Connecting to the RS-232C Port at the Host

 

 

Section 4-1

 

Device (e.g. SYSMAC support software) in accordance with the host model and

port.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection to

Word #

Writing

Setting

 

 

Value

 

 

 

 

 

 

 

 

 

 

 

 

 

C200HX/HG/HE(-Z)E, SRM1

DM6645

 

 

 

 

Built-in RS-232C port

 

 

 

 

 

 

 

 

 

 

 

 

Use NT link (1:N)

 

C200HX/HG/HE(-Z)E

 

 

 

Communication Board port A*1

DM6555

5j00

j = highest unit number of

 

CQM1H port 1*2

 

 

the connected PTs (1 to 7)

 

 

 

(*3)

 

 

C200HX/HG/HE(-Z)E

DM6550

 

 

 

 

Communication Board port B*1

 

 

 

 

 

 

 

 

*1

RS-232C port on the Communications Board

 

 

*2

RS-232C port on the Serial Communications Board

 

 

*3

When using a C200HE (-Z)E, the maximum PT unit number is 3.

Refer to the PC’s operation manual for details on changing PC Setup settings.

Setting the DIP Switches of a C200HX/HG/HE(-Z)E

When using a C200HX/HG/HE(-Z)E, the DIP switches on the front panel must be set as shown below in order to make the settings in the PC Setup area (data memory) effective.

RS-232C port communication condition setting

Set DIP SW5 to OFF to make the settings made in PC

Setup effective.

Connecting to CS1-series CPU Units

CS1-series CPU Unit: CS1G/H-CPUjj-E(V1)

The PT is connected to the built-in RS-232C port on the CPU Unit or an RS-232C port on a Communications Board. It can also be connected to the peripheral port on the CPU Unit, but a CS1W-CN118 Peripheral Port Connecting Cable must be used.

PC Setup

When connecting to a CS1 series CPU, set the following communication condi- tions for the PC Setup area, in accordance with the communication port to be used.

When using the built-in RS-232C port of CS1G/H

Word #

Writing Value

Settings

 

 

 

160

8200

NT link (1:N) mode

 

 

 

161

0000 to 0009 (*1)

Communications baud rate (standard)

166

000j

j = The largest model number of the

connected PT (0 – 7)

 

 

 

 

 

*1 Set any value between 0000 and 0009 Hex for the communications baud rate. The same baud rate will be used regardless of the value as long as it is between 0000 and 0009 Hex.

When using the peripheral port of CS1G/H

Word #

Writing Value

Settings

 

 

 

144

8200

NT link (1:N) mode

 

 

 

145

0000 to 0009 (*1)

Communications baud rate (standard)

150

000j

j = The largest model number of the

connected PT (0 – 7)

 

 

 

 

 

73

Page 84