Omron NT31 NT31C manual Setting the Memory Link Method

Models: NT31 NT31C

1 296
Download 296 pages 47.55 Kb
Page 175
Image 175

Setting Conditions for Communications with Host by Using Memory Switches

Section 6-7

6-7-5 Setting the Memory Link Method

Set the communication conditions for the host link method at serial port A or seri- al port B by following the operation from the System Menu shown below. Check the communication settings of the host to be used.

Ver 3.10

Select Maintenance Mode.

Select Memory Switch.

Display the fourth memory switch screen by pressing the [] (next screen) or [] (previous screen) touch switch.

Press the touch switch corresponding to the port at which the memory link method is to be set (Comm. A Method or Comm. B Method) to display the setting option Memory Link.

The setting option changes each time the touch switch is pressed.

In this example, serial port A is used.

Press the Set touch switch to the right of the port at which the setting has been made.

In this example, serial port A is used.

165

Page 175
Image 175
Omron NT31 NT31C manual Setting the Memory Link Method