Connecting a Bar Code Reader

Section 3-4

Settings at the Bar Code Reader

3-4-3 Data Format

Make the settings shown in the table below at the bar code reader. Make sure that the communications speed, parity, stop bit, and data bit settings match the communication settings made at the NT31/NT31C. For details on the setting method, refer to the instruction manual for the bar code reader used.

Item

Possible Settings

 

 

Communications speed

4800, 9600, 19200 bps

 

 

Parity

EVEN, ODD, NONE

 

 

Stop bits

1 or 2 bits

 

 

Data bits

7 or 8 bits

 

 

Preamble

STX

 

 

Postamble

ETX

 

 

RS/CS control

Available

 

 

Communication protocol

No-protocol mode

 

 

Transmission of number of bar code label digits

Transmission prohibited

 

 

Transmission of ID characters

Transmission prohibited

 

 

Bar code types

Multi-reading (all types can be

 

read)

 

 

Trigger switch setting

Automatic reading mode

About RS/CS Control

During bar code reading, the NT31/NT31C performs RS/CS control. When the Input Method setting of the NT31/NT31C is set to Auto, the RS signal is turned OFF, prohibiting the next input, until the read data has been notified to the host.

Because of this, when the Auto setting is made, the next input is not possible until the data has been notified to the host.

However, when the setting is Auto and the RS/CS signals of the cable are shorted, RS/CS control is ineffective. Consequently, data input from the bar code reader to the NT31/NT31C is updated regardless of whether or not the data is notified to the host.

For details, refer to the instruction manual for the bar code reader used.

The data format for communication when using the bar code input function of the NT31/NT31C is shown below.

STX

Data

Data

 

 

 

Data

ETX

 

 

 

 

 

 

 

 

(02H)

 

 

 

 

 

 

(03H)

The characters which are effective as data are hexadecimal codes from 20 to 7FH, and the maximum data length is 40 bytes.

Data which does not follow the data format described above is invalidated and discarded.