Connecting to the RS-232C Port at the HostSection 4-1

The host units that can be connected to the NT31/NT31C by the NT link (1:1) method using the RS-232C ports of both units are indicated in the table below.

 

CPUs with Built-in

CPUs Connectable with

Connectable

PC Series

Expansion

NT Link Function

Communication

to

 

 

 

Board(*1)

 

 

C200HS-CPU21-E, -EC

---

 

 

C200HS-CPU23-E

 

C200HS

 

C200HS-CPU31-E

 

 

 

 

 

C200HS-CPU33-E

 

 

 

 

 

 

 

C200HE-CPU42-(Z)E

C200HE-CPU32-(Z)E

C200HE (-Z)E

 

C200HE-CPU42-(Z)E

 

 

 

 

 

 

 

 

C200HG-CPU43-(Z)E

C200HG-CPU33-(Z)E

C200HG

 

C200HG-CPU43-(Z)E

 

C200HG-CPU63-(Z)E

C200HG-CPU53-(Z)E

(-Z)E

 

 

C200HG-CPU63-(Z)E

 

 

 

 

 

 

 

C200HX-CPU34-(Z)E

 

 

C200HX-CPU44-(Z)E

C200HX-CPU44-(Z)E

 

 

C200HX-CPU64-(Z)E

C200HX-CPU54-(Z)E

C200HX (-Z)E

 

X200HX-CPU65-ZE

C200HX-CPU64-(Z)E

 

 

 

C200HX-CPU85-ZE

C200HX-CPU65-ZE

 

 

 

C200HX-CPU85-ZE

 

 

 

 

 

 

CPM1-10CDR-j(*2)

---

 

C series

CPM1-20CDR-j(*2)

 

 

CPM1-30CDR-j(*2)

 

 

 

 

 

 

CPM1A-10CDj-j(*2)

 

CPM1

 

CPM1A-20CDj-j(*2)

 

 

 

CPM1A-30CDj-j(*2)

 

 

 

CPM1A-40CDj-j(*2)

 

 

 

CPM2A-30CDjj-j

---

CPM2A

 

CPM2A-40CDjj-j

 

 

CPM2A-60CDjj-j

 

 

 

 

 

 

 

CPM2C-10jjjjjj-j(*3)

---

CPM2C

 

CPM2C-20jjjjjj-j(*3)

 

 

 

 

 

CQM1-CPU41-EV1

---

 

 

CQM1-CPU42-EV1

 

 

 

CQM1-CPU43-EV1

 

CQM1

 

CQM1-CPU44-EV1

 

 

 

CQM1-CPU45-EV1

 

 

 

 

 

 

 

CQM1H-CPU21-E

CQM1H-CPU51 (*4)

 

 

CQM1H-CPU51-E

CQM1H-CPU61 (*4)

CQM1H

 

CQM1H-CPU61-E

 

 

 

 

 

 

 

CV500-CPU01-EV1

---

CV500

CV series (*5)

 

 

 

CV1000-CPU01-EV1

---

CV1000

 

CV2000-CPU01-EV1

---

CV2000

 

 

 

 

CVM1 series

CVM1-CPU01-EV2

---

 

CVM1-CPU11-EV2

 

CVM1

(*5)

 

 

CVM1-CPU21-EV2

 

 

CompoBus/S

 

---

 

master

SRM1-C02-V1

 

SRM1

control unit

 

 

 

*1 One of the following communication boards is required: C200HW-COM02/COM04/COM05/COM06-EV1.

*2 A CPM1-CIF01 adapter is required.

*3 Use a CPM2C-CN111 or CS1W-CN114/118 Connecting Cable, CPM1-CIF01 RS-232C Adapter, or CPM1-CIF11 RS-422A Adapter to connect.

*4 A CQM1H-SCB41 Serial Communications Board is required.

*5 CPUs of CVM1/CV series PCs without the suffix -EVjcannot be connected.

Reference: CS1 series CPU cannot be connected with the 1:1 connection NT link method. Use the 1:N connection NT link method (standard or high-speed) instead to make the 1:1 connection. For details, refer to Using the NT Link (1:N) Method (page 72) or Using the High-speed NT Link (1:N) Method (page 75).

68

Page 79
Image 79
Omron NT31 NT31C manual Connecting to the RS-232C Port at the HostSection