Using an RS-232C/RS-422A Convertor Unit

Appendix C

 

 

 

Pin Arrangement

The convertor unit has a terminal block for an RS-422A/485 interface connection and a connector for an RS-232C interface connection.

The pin arrangements for the RS-422A/485 terminal block and the RS-232C connector are as follows.

RS-422A/485 Terminal Block

7

5

3

1

 

Terminal

 

 

Signal direction

 

block pin

Signal name

Abbreviation

(convertor unit RS-422

8

No.

 

 

device)

 

 

 

 

8

Request to send ()

CSA

6

 

 

 

 

7

Request to send (+)

CSB

4

 

 

 

 

6

Receive data ()

RDA

2

 

 

 

 

5

Receive data (+)

RDB

 

 

 

 

 

 

 

4

Send data ()

SDA

 

 

 

 

 

 

3

Send data (+)

SDB

 

 

 

 

 

 

2

Signal ground

SG (GND)

 

 

 

 

 

 

1

Functional ground

 

* The CSB and CSA signals are for specialized applications.

RS-232C Connector

 

 

Connector

 

 

Signal direction

 

 

Signal name

Abbreviation

(convertor unit RS-232C

 

 

pin No.

 

 

 

 

device)

 

 

 

 

 

1

 

 

 

 

 

6

1

Not used

2

7

 

 

 

 

2

Send data

SD

3

8

 

 

 

 

3

Receive data

RD

4

9

 

 

 

 

5

4

Request to send

RS

 

 

 

 

(shorted to CS internally)

 

 

 

 

 

 

 

 

 

 

5

Clear to send

CS

 

 

 

(shorted to RS internally)

 

 

 

 

 

 

 

 

 

 

6

+5 V (150 mA) input for convertor

+5 V

 

 

 

unit

 

 

 

 

 

 

 

 

 

 

7

Data set ready

DR

 

 

 

(shorted to ER internally)

 

 

 

 

 

 

 

 

 

 

8

Data terminal ready

ER

 

 

 

(shorted to DR internally)

 

 

 

 

 

 

 

 

 

 

9

Signal ground

SG

* The hood is connected to the functional ground terminal of the RS-422A terminal block.

263