System Settings

Section 6-9

The four memory switch setting screens are shown below.

[] (next screen)

[] (next screen)

[] (previous screen)

[ ] (previous screen)

[ ] (next screen)

[] (next screen)

[] (previous screen)

[] (previous screen)

Memory Switch Settings

A list of the memory switch settings is presented below.

Start-up Wait Time

page 169

Key Press Sound

page 170

Buzzer Sound

page 171

Printer Controller

page 172

Print Method

page 174

Screen Saver Movement

page 175

Screen Saver Start up Time

page 177

Hist. Disp. Method

page 179

Resume Function

page 181

Comm. Auto-return

page 183

Time-out Interval

page 185

Retry Counts

page 186

Comm. A Method

page 157

(For the bar code reader, refer to page 188.)

Comm. B Select

page 167

Comm. B Method

page 157

For details on each setting, refer to the pages indicated.

6-9-2 Setting the Start-up Wait Time

The Start-up Wait Time is the time lapse until the NT31/NT31C switches to the RUN mode after its power has been switched ON or after it has been reset. Set this item if it takes some time for the host to start operation. Nothing is displayed during the Start-up Wait Time.

The setting range is 0 to 10 seconds. The default (factory) setting is 00sec.

169