3-6-1 Installation Method

Install the memory unit (NT-MF261) at the expansion interface connector at the rear of the NT31/NT31C as shown in the figure below. (The expansion interface connector is located underneath the note label.)

Mounting screws

3-6-2 Method of Use

As shown in the figure below, a memory unit has two sets of four DIP switches, and the operation is determined by the DIP switches that are set at startup.

1 2 3 4

OFF

1 2 3 4

OFF

Factory setting is turned all to off.

SW1 SW2

Note 1. Always confirm that the power to the NT31/NT31C is off before setting the DIP switches.

 

2. Do not touch the PCB (printed circuit board) directly with bare hands.

DIP Switch Functions

The functions of the DIP switches on the memory unit are indicated in the table

 

below.

 

 

 

 

SW1

 

 

 

 

 

 

 

 

 

 

 

Switch

 

Function

 

 

 

 

 

 

 

 

 

SW1-1

Automatic transmission (writing from the memory

OFF: Not executed

 

 

 

 

 

unit to the PT)

 

ON : Executed

 

 

 

 

 

 

 

 

 

 

 

 

SW1-2

Automatic transmission (writing from the PT to

OFF: Not executed

 

 

 

 

 

the memory unit)

 

ON : Executed

 

 

 

 

 

 

 

 

 

 

 

 

SW1-3

Manual transmission (Direction of transmission

OFF: Not executed

 

 

 

 

 

and bank used selected at the PT touch panel)

ON : Executed

 

 

 

 

 

 

 

 

 

 

SW1-4

Reserved for system use (must be set to OFF)

 

 

SW2

 

 

 

 

 

 

 

 

 

 

 

Switch

 

Function

 

 

 

 

 

 

 

 

 

SW2-1

Disable/enable writing to PT

 

OFF: Disable

 

 

 

 

 

 

 

ON : Enable

 

 

 

 

 

 

 

 

 

 

 

 

 

SW2-2

Disable/enable writing to the memory unit

OFF: Disable

 

 

 

 

 

ON : Enable

 

 

 

 

 

 

 

 

 

 

 

 

 

SW2-3

Area (bank) selection of automatic transmission.

OFF: Bank 0

 

 

 

 

 

ON : Bank 1

 

 

 

 

 

 

 

 

 

 

 

 

SW2-4

Reserved for system use (must be set to OFF)

 