■Resetting the Alarm Inputs
There are two alarm reset functions:
•Alarm reset (resetting the alarm inputs per monitor)
•Alarm all reset (resetting all the alarm inputs)
●Alarm Reset
RESET |
|
|
|
ALL RESET |
|
|
|
TOUR SEQ | T&D | CAM ID | EVENT |
| STILL | AUX1 OFF | AUX1 ON |
1.Select a monitor which displays "ALARM".
2.To reset the alarms, press the RESET button. "ALARMnn" will disappear from the selected moni- tor.
When alarms have been reset from all the monitors, the LED display and indicators of system controllers will work as follows for recovery.
•The LED display will return to the state before the alarm input.
•The alarm indicator will go out.
•The CAM indicator will return to the state before the alarm input.
Note: When more than one alarm is input and they are associated with the same monitor, they cannot be reset one by one.
●Alarm All Reset
1.Press the RESET button while holding down the SHIFT button.
RESET |
|
|
|
ALL RESET |
|
|
|
TOUR SEQ | T&D | CAM ID | EVENT |
| STILL | AUX1 OFF | AUX1 ON |
NEXT | MON STATUS | ALL |
|
| AUX2 OFF | AUX2 ON | |
PAUSE | ALM H | VLD H | SYS S |
PAUSE | SEQUENCE | DEF OFF | DEF ON |
| MON (ESC) |
| CAM (SET) |
SHIFT | MON LOCK | MULTI SCREEN SEL | WIPER |
2.The monitor, the LED display and the indicator will change as follows:
"ALARMnn" will disappear from all the monitor.
The LED display will return to the state before the alarm input.
The alarm indicator will go out.
The CAM indicator will return to the state before the alarm input.
■Suspending the Alarm Inputs
Use this function when you do not want to be disturbed by an alarm input, for example, during the setup procedures.
ACK | RESET |
|
|
SUSPEND | ALL RESET |
|
|
GROUP SEQ | TOUR SEQ | T&D | CAM |
REW/FF | STILL | AUX1 O | |
PREV | NEXT | MON STATUS ALM SUSPENDED | |
STEP |
| AUX2 O | |
| PAUSE | ALM H | VLD |
PLAY | PAUSE | SEQUENCE | DEF O |
OSD |
| MON (ESC) |
|
| SHIFT | MON LOCK | MULTI SCRE |
1.Press the ACK/SUSPEND button while holding down the SHIFT button.
"ALM SUSPENDED" will appear on the monitor.
2.To cancel alarm suspension, press the ACK/SUSPEND button while holding down the SHIFT button again. "ALM SUSPENDED" will disappear from the monitor.
Notes:
•An alarm continues to operate even after it is suspend- ed.
•If you suspend an alarm while an alarm image is dis- played, "ALM SUSPENDED" will not appear on the moni- tor. Reset the alarm, and then suspend it again.