![](/images/new-backgrounds/1205226/205226371x1.webp)
ALARM CONTROL
Note: This section describes the terminal mode. To operate in the PS·Data mode, refer to the operating instructions.
■Alarm Mode
When alarm (sensor) is accepted, the matrix switcher's operation mode changes to the alarm mode. Then, the sys- tem operates as follows:
•The camera image (alarm image) appears on the moni- tor.
In the factory default setting, the alarm inputs 1 to 16 are associated with the
•"ALARMnn" appears on the monitor. (nn is the alarm number).
ALARM01
•Alarm output signals are supplied from Alarm Output 1 to 4 (#10, 11, 23 and 24) of the ALARM port
•The alarm number and "Alarm" sign will appear on the LCD. Then, "Alarm" sign and the alarm indicator will blink.
■Operation during an Alarm Mode
While an alarm mode is active, the following are available from the system controller:
•Operating the camera with the alarm input (ACK)
•Resetting the alarm (ALM RESET/ALM ALL RESET)
•Suspending the alarm (ALM SUSPENDED)
■Operation of an Alarm-related Camera (ACK)
You can operate the camera with the alarm input as follows:
ACK
1.Select a monitor which displays "ALARM".
2.Press the ACK button.
"ACK" will appear on the monitor with an alarm input. The camera with an alarm input will become operable.
3.Operate camera with the system controller. Panning, tilting, zoom, focus, and iris are available. When selecting another monitor, "ACK" will disappear from the display. The matrix switcher system will return to the alarm mode.
Mon1 Cam01 | AL01 |
Alarm |
|
There are two operation modes when more than one alarm signal has been accepted by the matrix switcher that is assigned to the same monitor.
•Sequence mode: An alarm operation is replaced by another one after the dwell time ends.
•Hold mode: An initial alarm operation is continued even after another alarm input is accepted.
Notes:
•The association of the alarm inputs with cameras and monitors are changeable in SETUP MENU or WJ- SX150A Administrator Console. (Refer to the operating instructions of matrix switcher.)
•Alarm input will be automatically reset in 30 seconds. The
14 | the operating instructions of matrix switcher.) |
|