RUNNING SEQUENCE
Note: This section describes the terminal mode. To operate in the PS·Data mode, refer to the operating instructions.
■Tour Sequence
The following functions are available if a tour sequence has been previously configured through SETUP MENU or WJ- SX150A Administrator Console. Any tour sequence can be assigned to any monitors.
1.Select the desired monitor and camera. (Refer to p. 3 Monitor Selection and p. 3 Camera Selection.)
2.To select the desired tour sequence number, press the numeric buttons.
3.When you have selected a wrong number, press the CLEAR button to clear the numeric input.
4.Press the TOUR SEQ/GROUP SEQ button to run the tour sequence in the forward direction on the active monitor.
Mon1 Cam01
T04
5.Press the SEQ PAUSE/SEQ STOP button to pause a tour sequence on the active monitor.
The "P" sign (indicating the pause status) is displayed at the tour sequence number on the active monitor, and a camera number currently selected appears on the LCD.
Mon1 Cam07
T04P
•Press the SEQ PAUSE/SEQ STOP button to restart a tour sequence forward from the next step that was pre- viously paused.
•Press the + button to move the sequence one frame to the next step from the step that was previously paused.
•Press the – button to move the sequence one frame to the previous step from the step that was previously paused.
6.Press the SEQ PAUSE/SEQ STOP button while holding down the SHIFT button to stop a tour sequence on the active monitor and return to spot monitoring.
■Group Sequence
The following function is available only if a group sequence has been previously established in
As described earlier, a group sequence determines the assignment of monitors and cameras. Therefore, monitor selection is not required.
1.Press the numeric buttons to select a desired group sequence number.
2.When you have selected a wrong number, press the CLEAR button to clear the numeric input.
3.Press the TOUR SEQ/GROUP SEQ button while holding down the SHIFT button to run a group sequence for- ward on the assigned monitors.
Mon1 Cam01
T01
4.Press the SEQ PAUSE/SEQ STOP, + or – button to operate the group sequence. Refer to Step 5 of Tour Sequence in this page for how to use these buttons.
5.To stop the sequence, select one of the monitors that are being run on the selected group sequence, then press the SEQ PAUSE/SEQ STOP button while holding down the SHIFT button
Note: If an alarm is activated during a sequence pause, the sequence runs again after the matrix switcher recovers from the alarm mode.
10