PS·Data Connection

1.Set the unit address of the recorder to 5 or larger.

2.Set the [Camera control] setting to “PSD” for all cameras in SETUP MENU of the recorder.

3.Connect the unit’s CAM OUT 1 to 16 connectors to the recorder’s VIDEO IN 1 to 16 connectors with a coaxial cable.

4.Connect the unit’s DATA4 Port connector to the recorder’s DATA port with a modular cable.

Select the recorder’s new unit address, which is set in Step 1, in 600 RECORDER of SETUP MENU or the Recorder window of WJ-SX150A Administrator Console. (Refer to this unit’s operating instructions.)

System controller (Terminal Mode)*

 

 

 

 

 

 

 

 

 

 

 

 

 

EXT IN

 

3

 

 

 

 

ALARM

 

 

 

SERIAL

 

 

 

 

(PLAY IN)

 

 

 

 

 

 

 

DATA HDR DATA 4

DATA 3

DATA 1

RS485(CAMERA)

 

CAMERA

 

 

 

 

 

 

 

 

DATA 2

 

LINE

 

SW IN

 

 

 

 

 

 

TERM

 

 

 

 

2

SELECT

4

 

 

 

 

 

 

 

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXT OUT

 

4

 

 

 

 

 

 

PS•DATA

 

RS485(CAMERA)

 

 

 

 

(REC OUT)

 

MONITOR OUT

16

15

14

13

12

11

10

9

8

7

6

 

5

4

3

2

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

15

14

13

12

11

10

9

8

7

6

 

5

4

3

2

 

 

 

 

 

 

 

CAMERA

 

 

 

 

 

 

 

 

 

Monitor

MONITOR OUT

1

SIGNAL GND

2

POWER

1

 

 

AC IN

1

DATA 4*

 

(PS·Data)

Matrix Switcher

DATA

3

1

 

1

 

 

 

 

 

 

SERIAL

ALARM

 

 

CASCADE

 

 

 

4

2

OUT

2

 

 

AUDIO IN

AUDIO OUT

 

MONITOR OUT CASCADE IN

MONITOR (VGA)

ALARM/CONTOROL

 

 

 

SIGNAL GND

 

MODE

 

COPY 1

 

2

1

 

 

 

 

POWER

DATA

RS485(CAMERA)

10/100BASE-T EXT STORAGE

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC IN

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

 

 

 

 

 

 

 

VIDEO

 

 

 

 

 

 

 

 

MONITOR

 

 

 

 

 

 

 

MONITOR

Recorder*

OUT z

 

 

 

 

 

 

 

OUT x

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Monitor Monitor

System controller (PS·Data)

* Recorder control from system controllers connected to the matrix switcher is not available.

Notes:

Select the PS·Data protocol for the DATA 4 setting. (Refer to this unit’s operating instructions.)

If the recorder’s unit address, set in Step 1, and the recorder setting, set in Step 5, are different, the recorder will not be operable.

Do not connect the recorder to the DATA HDR port.

From system controllers connected to the unit, you cannot control the recorder.

Only one matrix switcher can be connected in the PS·Data mode.

39