To Control a Recorder via the Network

The following is the description of the connection between a recorder and this unit to control the recorder via the network.

1.Set the recorder's unit address to a number 5 or larger . (Refer to the recorder's operating instructions.)

2.Connect the unit’s CAM OUT 1 to 8 connectors to the recorder’s VIDEO IN 1 to 8 connectors with a coaxial cable.

3.Connect the unit’s EXT IN connector to the recorder’s MULTI SCREEN OUT connector with a coaxial cable.

4.Connect the unit’s DATA HDR and DATA4 connectors to the recorder’s DATA port with a daisy chain connection cable kit (WV-CA48/10K).

5.Select the recorder’s new unit address, which is set in Step 1, in 600 RECORDER (refer to p. 71 ) of SETUP MENU or the Recorder (refer to p. 97) window of WJ-SX150A Administrator Console.

6.Through a browser or the recorder’s SETUP MENU, set the CTL-UNIT ADDR to a number other than 1. (Refer to the recorder’s operating instructions.)

Matrix Switcher

16

15

14

13

Monitor

 

 

 

 

 

 

 

 

 

 

 

MONITOR OUT

 

 

 

 

 

 

 

 

 

EXT IN

 

3

1

SIGNAL GND

ALARM

 

 

 

SERIAL

 

 

 

(PLAY IN)

 

 

 

 

 

 

 

 

RS485(CAMERA)

 

CAMERA

 

 

 

 

 

 

DATA HDR DATA 4

DATA 3

DATA 2

DATA 1

 

SW IN

 

 

 

 

TERM

LINE

 

 

 

EXT IN

 

 

 

 

 

2 SELECT 4

 

 

 

 

 

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER

 

 

 

 

 

 

 

 

EXT OUT

 

4

2

 

 

 

 

 

 

 

 

 

 

 

 

PS•DATA

 

RS485(CAMERA)

 

 

 

(REC OUT)

 

MONITOR OUT

 

 

12

11

10

9

8

7

6

5

4

3

2

1

 

IN

AC IN

OUT

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

 

 

 

 

 

 

 

CAMERA

 

 

 

 

 

 

 

 

DATA HDR

DATA 4

CAMERA

 

OUT 1 to 8

 

(PSDATA)

 

 

VIDEO IN

 

 

 

 

 

 

 

MULTI

 

 

(WV-CA48/10K)

 

 

 

 

 

 

 

 

 

 

 

1 to 8

 

 

 

 

 

 

 

SCREEN OUT

DATA

 

IN

8

7

6

5

4

3

2

1

 

 

 

POWER

 

IN

 

 

 

 

 

 

 

SPOT

 

 

 

ON

 

 

 

 

 

 

 

 

 

ALARM/REMOTE

 

 

SIGNAL GND

 

 

 

 

 

 

 

 

OUT

 

 

 

 

OUT

 

 

 

 

 

 

 

 

 

 

 

OFF

 

OUT

8

7

6

5

4

3

2

1

 

 

 

 

 

AUDIO

 

 

 

VIDEO

 

 

 

MULTI

RS-232C

MODE

10/100BASE-T

DATA

 

 

 

 

 

 

 

SCREEN OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recorder

 

 

 

 

 

 

 

 

 

 

LAN Cable

 

 

 

 

 

 

 

 

 

 

 

 

 

LAN *

 

HUB/Router

* LAN: Local Area Network

Notes:

Select the PS·Data protocol for the DATA 4 setting. (Refer to p. 74 CAMERA/DATA1 – 4 PORT or p. 96 Data Port.) If the ter- minal mode is selected, you cannot control the recorder.

The recorder will not be operable if its unit address is set to 1/2/3/4.

If the recorder's unit address in Step 1 and the recorder setting in Step 5 are different, the recorder will not be operable.

In these connections, you cannot use a PS·Data system controller.

If you use two WJ-HD200 Series recorders, you cannot control the recorders with the system controller connected to the Master unit. When recording the images from CAM IN 1 to 16, it is recommended to use WJ-HD500 Series recorders.

44