![](/images/new-backgrounds/1205226/20522683x1.webp)
●To Control a Recorder via the Network
The following is the description of the connection between a recorder and this unit to control the recorder via the network.
1.Set the recorder's unit address to a number 5 or larger . (Refer to the recorder's operating instructions.)
2.Connect the unit’s CAM OUT 1 to 8 connectors to the recorder’s VIDEO IN 1 to 8 connectors with a coaxial cable.
3.Connect the unit’s EXT IN connector to the recorder’s MULTI SCREEN OUT connector with a coaxial cable.
4.Connect the unit’s DATA HDR and DATA4 connectors to the recorder’s DATA port with a daisy chain connection cable kit
5.Select the recorder’s new unit address, which is set in Step 1, in 600 RECORDER (refer to p. 71 ) of SETUP MENU or the Recorder (refer to p. 97) window of
6.Through a browser or the recorder’s SETUP MENU, set the
Matrix Switcher
16 | 15 | 14 | 13 |
Monitor
|
|
|
|
|
|
|
|
|
|
| MONITOR OUT |
|
|
|
|
|
|
|
|
| EXT IN |
| 3 | 1 | SIGNAL GND |
ALARM |
|
|
| SERIAL |
|
|
| (PLAY IN) |
|
|
|
|
|
|
|
| RS485(CAMERA) |
| CAMERA |
|
|
|
| ||
|
| DATA HDR DATA 4 | DATA 3 | DATA 2 | DATA 1 |
| SW IN |
|
|
|
| |
TERM | LINE |
|
|
| EXT IN |
| ||||||
|
|
|
| 2 SELECT 4 |
|
|
|
|
| |||
OFF | ON |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| POWER | |
|
|
|
|
|
|
|
| EXT OUT |
| 4 | 2 | |
|
|
|
|
|
|
|
|
|
| |||
|
| PS•DATA |
| RS485(CAMERA) |
|
|
| (REC OUT) |
| MONITOR OUT |
|
|
12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 |
|
IN
AC IN
OUT
16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 |
|
|
|
|
|
|
| CAMERA |
|
|
|
|
|
|
|
|
DATA HDR | DATA 4 | CAMERA |
| OUT 1 to 8 | |
| (PS•DATA) | |
|
|
VIDEO IN |
|
|
|
|
|
|
| MULTI |
|
| |||
|
|
|
|
|
|
|
|
|
|
| |||
1 to 8 |
|
|
|
|
|
|
| SCREEN OUT | DATA |
| |||
IN | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 |
|
|
| POWER |
|
IN |
|
|
|
|
|
|
| SPOT |
|
|
| ON |
|
|
|
|
|
|
|
|
| ALARM/REMOTE |
|
| SIGNAL GND | ||
|
|
|
|
|
|
|
| OUT |
|
|
|
| |
OUT |
|
|
|
|
|
|
|
|
|
|
| OFF |
|
OUT | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 |
|
|
|
|
|
AUDIO |
|
|
| VIDEO |
|
|
| MULTI | MODE | DATA |
| ||
|
|
|
|
|
| SCREEN OUT |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
Recorder |
|
|
|
|
|
|
|
|
|
| LAN Cable |
| |
|
|
|
|
|
|
|
|
|
|
|
| LAN * |
|
HUB/Router
* LAN: Local Area Network
Notes:
•Select the PS·Data protocol for the DATA 4 setting. (Refer to p. 74 CAMERA/DATA1 – 4 PORT or p. 96 Data Port.) If the ter- minal mode is selected, you cannot control the recorder.
•The recorder will not be operable if its unit address is set to 1/2/3/4.
•If the recorder's unit address in Step 1 and the recorder setting in Step 5 are different, the recorder will not be operable.
•In these connections, you cannot use a PS·Data system controller.
•If you use two
44