RUNNING SEQUENCE
■Tour Sequence
The following functions are available if a tour sequence has been previously configured through SETUP MENU or WJ- SX150A Administrator Console. Any tour sequence can be assigned to any monitors.
1.Select the desired monitor. (Refer to p. 125 Monitor Selection.)
2.To select the desired tour sequence number, press the numeric buttons.
3.Press the SEQ button to run the tour sequence in the forward direction on the active monitor.
4.Press the SEQ PAUSE button to pause a tour sequence on the active monitor.
A series of camera picture appear in pause on the mon- itor screen.
5.Press the SEQ PAUSE button again to restart a tour sequence forward from the next step that was previous- ly paused by pressing the SEQ PAUSE button.
6.Press the SHIFT button, and then press the + button to move the sequence one frame to the next step from the step that was previously paused by pressing the SEQ PAUSE button.
Press the SHIFT button, and then press the - button to move the sequence one frame to the previous step from the step that was previously paused by pressing the SEQ PAUSE button.
7.Select a camera (refer to the system controller's operat- ing instructions) to stop the sequence. The monitor will return to the spot mode.
■Group Sequence
The following function is available only if a group sequence has been previously established in
As described earlier, a group sequence determines the assignment of monitors and cameras. Therefore, monitor selection is not required.
1.Press the numeric buttons to select a desired group sequence ID number.
2.Press the SEQ button to run a group sequence forward on the assigned monitors.
3.Press the SEQ PAUSE button to pause a tour sequence on the active monitor.
A series of camera picture appear in pause on the mon- itor screen.
4.Press the SEQ PAUSE button again to restart a group sequence forward from the next step that was previous- ly paused by pressing the SEQ PAUSE button.
5.Press the SHIFT button, and then press the + button to move the sequence one frame to the next step from the step that was previously paused by pressing the SEQ PAUSE button.
Press the SHIFT button, and then press the – button to move the sequence one frame to the previous step from the step that was previously paused by pressing the SEQ PAUSE button.
6.Select a camera (refer to the system controller’s operat- ing instructions) to stop the sequence. The assigned monitors will return to the spot mode.
Note: If an alarm is activated during a sequence pause, the sequence runs again after the unit recovers from the alarm mode.