Problem | Check item | Remedy |
The camera image is dim.
Dust may be sticking on the camera lens.
Remove the dust from the camera lens.
The camera’s lens focus may not be proper.
Press the FOCUS NEAR/ FAR buttons to adjust the lens focus. If the camera sup- ports auto focus, press these buttons simultaneously. The lens focus can be adjusted automatically.
The camera’s cable compensation set- ting may not be proper.
Open 730 COMPENSATION/VD2/DATA (refer to p. 74) or the Cable Compensa- tion/VD2 window (refer to p. 94) to con- firm the setting.
The camera is not operable.
The camera may not have been select- | Select the camera again. (Refer to p. |
ed. | 107.) |
|
|
The camera may not support the function | Confirm whether the camera supports |
you try to execute. | the function. (Refer to the camera's oper- |
| ating instructions.) |
|
|
The camera's cable setting may wrong. | Open 730 COMPENSATION/VD2/DATA |
| (refer to p. 74) or the Cable |
| Compensation/VD2/DATA (refer to p. 94) |
| window to confirm the setting. If the cam- |
| era’s DATA is set to OFF, the cameras |
| will not be operable. |
|
|
The data port setting may wrong. | Open the Data Port window (refer to p. |
| 96) and confirm the setting. |
| When the BUSY indicator is lighting on | • Select another camera. |
| the system controller, a | • Wait until a |
| operator has selected the camera. | ishes controlling the camera. |
|
|
|
| While the PROHIBITED indicator is light- | Open the Operator Registration window |
| ing on the system controller, you are pro- | (refer to p. 90) and reconfigure the set- |
| hibited to control the camera. | ting. |
|
| |
OSD items (Clock, Camera title, Monitor | • Turn off an overlapping item. (Refer to | |
status, Event) overlap one another. | p. 115.) | |
|
| • Move OSD items. (Refer to p. 115.) |
|
| • Change the area title display position |
|
| through the camera’s setup menu. |
|
| (Refer to the camera’s operating |
|
| instructions.) |
Tour/group sequence is not activated.
The tour/group sequence setting may be | Open 300 SEQUENCE (refer to p. 66), |
wrong. | the Tour Sequence (refer to p. 84) or |
| Group Sequence (refer to p. 85) window |
| and reconfigure the setting. |
|
|
The setting has not been put from the PC | Put the file to the unit again after the con- |
to the unit. | figuration. (Refer to p. 83 Put a file to |
| SX150A.) |
When the PROHIBITED indicator is light- ing on the system controller, you are pro- hibited to control the camera.
Open 800 OPERATOR REGISTRATION (refer to p. 76) or the Operator Registration window (refer to p. 90) and reconfigure the setting.