420 ALARM EVENT

2 of 10

ALM MON MODE

REC ALARM PORT

LCN(PRE)/TOUR

 

111 LCN 11 / PRE01 R0 MASTER / 11

121 LCN 12 / PRE01 R0 MASTER / 12

131 LCN 13 / PRE01 R0 MASTER / 13

141 LCN 14 / PRE01 R0 MASTER / 14

151 LCN 15 / PRE01 R0 MASTER / 15

161 LCN 16 / PRE01 R0 MASTER / 16

171 LCN 17 / PRE01 R2 SLAVE1 / 1

181 LCN 18 / PRE01 R2 SLAVE1 / 2

191 LCN 19 / PRE01 R2 SLAVE1 / 3

201 LCN 20 / PRE01 R2 SLAVE1 / 4

LCN:LOGICAL CAMERA NUMBER

420 ALARM

EVENT

10 of 10

ALM MON MODE

REC ALARM PORT

 

 

LCN(PRE)/TOUR

 

91

1

LCN 91 / PRE01

 

92

1

LCN 92 / PRE01

 

93

1

LCN 93 / PRE01

 

94

1

LCN 94 / PRE01

 

95

1

LCN 95 / PRE01

 

96

1

LCN 96 / PRE01

 

97

1

LCN 97 / PRE01

 

98

1

LCN 98 / PRE01

 

99

1

LCN 99 / PRE01

 

LCN:LOGICAL CAMERA NUMBER

ALM: This stands for the alarm event number.

MON: This stands for the monitor number.

MODE: This stands for the preset position of a camera or tour sequence number activated with an alarm input signal.

LCN(PRE)/TOUR: Activates a spot camera or tour sequence with an alarm input. To activate a spot camera, select LCN nn (nn is a logical camera num-

ber: 01 to 99). To activate a tour sequence, select

TUR nn (nn is a tour number: 01 to 32).

When you selected a combination camera for LCN nn, enter the desired preset position number. PRE 01 to 64 is available. When you selected another type of camera, select “-“.

REC: This stands for a recorder activated with an alarm input signal. If no recorder is activated, the parame- ter will be a space. The REC area displays the num- ber of recorder which receives images from a cam- era whose logical camera number is correspondent with the alarm event number.

R0 to R4 shows the following.

Recorder number

Recorder

 

 

R0

Master recorder

 

 

R1

Slave 1 recorder

 

 

R2

Slave 2 recorder

 

 

R3

Slave 3 recorder

 

 

R4

Slave 4 recorder

 

 

Note: If a WJ-HD200 Series recorder is connected to CAM 1 to 8, recorder number will be displayed even camera channels (CAM 9 to 16) not connect- ed to the recorder.

ALARM PORT: When an alarm port pin set here receives an input signal, the designated event is activated. MASTER, SLAVE 1 to 4 is available for the matrix switcher. 1 to 16 is available for the alarm port number. To deactivate the alarm number, press the button 0. ALARM PORT will be a space.

The factory default setting is same as the illustrations.

Notes:

MODE and LCN(PRE/TOUR) cannot be selected by pressing the numeric buttons. Press the NEXT or PREV button for selection.

PRE doesn’t appear when TOUR 1 to 16 is selected for MODE.

When selecting a camera without the preset position function, select "- -" for PRE.

When moving the joystick to at the bottom of ALARM EVENT 1 of 10, the monitor will display 2 of 10 (the next page).

When moving the joystick to at the top of ALARM EVENT 2 of 10, the monitor will display 1 of 10 (the pre- vious page).

Each ALARM PORT can be assigned to only one alarm number. If you enter the same ALARM PORT more than one time, the newer will be activated and the older will be changed to a space.

An alarm event will be activated even if the selected logical camera number is not assigned to any camera channel.

In this case, black image and “NOT ASSIGN” will be displayed on the monitor.

Set the parameter of a port number area by pressing the numeric button(s).

If you press the NEXT or PREV button at a port pin num- ber area, the parameter will be switched among a space and ALARM PORT not assigned to other alarm events.

After the configuration, press the MON (ESC) button. The monitor display returns to ALARM SETUP.

• ALARM INPUT

430 CAMERA

This stands for that an alarm input is accepted via the CAMERA IN connectors or the RS-485 ports.

ON: The alarm-associated sequence/spot image is dis- played on a monitor, and alarm recording will start (if a recorder is connected to the unit).

REC ONLY: Only alarm recording will start and moni- tors will keep displaying the current sequence/spot images.

Note: You cannot recover alarm-related operations from system controllers when REC ONLY is selected.

OFF: An alarm input is accepted neither via the CAM- ERA IN connectors nor the RS-485 ports.

The factory default setting is OFF.

440 ALARM PORT

This stands for that an alarm input is accepted via the ALARM port (25-pin D-sub connector at the rear panel).

ON: The alarm-associated sequence/spot image is dis- played on a monitor, and alarm recording will start (if a recorder is connected to the unit.)

68

Page 65
Image 65
Panasonic WJ-SX 150A manual Alarm Input