Secret View: Select the desired setting by clicking on the
ON: The adjoining
OFF: Secret view function is unavailable.
The factory default setting is OFF.
Sequence Mode: Select the sequence type by clicking on the radio button.
Quad: Multiplexer sequence is activated. The moni- tor display will be changed as 4A → 4B → 4C
→4D.
3+1: Images are displayed in 4 multiscreens, and the images of Camera 4 to 16 are displayed in the sequence mode, at the right bottom of the monitor. The images of Camera 1 to 3 are fixed. (Refer to the
8+1: Images are displayed in 9 multiscreens, and the images of Camera 9 to 16 are displayed in the sequence mode, at the right bottom of the monitor. The images of Camera 1 to 8 are fixed. (Refer to the
The factory default setting is Quad.
Dwell: The dwell time of the selected sequence mode is selectable. 2S to 30S is available.
The factory default setting is 2S.
• REC OUT Group
Title Display: Select the desired setting by clicking on the
ON: The camera title is displayed on the recorded image.
OFF: The camera title is not displayed on the recorded image.
The factory default setting is ON.
Clock Display: Select the desired setting by clicking on the
ON: The date and time are displayed on the record- ed image.
OFF: The date and time are not displayed on the recorded image.
The factory default setting is ON.
Normal Group
REC Mode: Select the desired setting by clicking on the radio button.
EXT: Select this to
INT: Select this if the asynchronous unit is connect- ed to the unit. When it is activated, the drop- down menu becomes also active so that you can select the desired normal recording rate. 002, 004 to 255 (field) are selectable.
The factory default setting is EXT.
Alarm Group
REC Mode: Select the desired setting by clicking on the radio button.
EXT: Select this to
INT: Select this if the asynchronous unit is connect- ed to the unit. When it is activated, the drop- down menu becomes also active so that you can select the desired normal recording rate. 002, 004 to 128 (field) are selectable.
The factory default setting is EXT.
DYNAMIC REC: Select the desired setting by clicking on the
GROUP: Select this to give recording priority to a group of up to 4 camera channels associated to the alarm input. When you select this, the Group Setting button becomes active. By pressing the button, the Mux Alarm Group window will be displayed so that you can configure the Group 1 to 16 parameters. (Refer to p. 100 Mux Alarm Group.)
OFF: Select this to deactivate the alarm priority mode.
The factory default setting is OFF.
• System Group
Camera SW Loss: Select the desired setting by click- ing on the
ON: “CAM SW LOSS” will blink on the associated monitor when loss of the camera switching pulse is detected.
OFF: “CAM SW LOSS will not appear on the moni- tor.
The factory default setting is ON.
Dummy Black: Select the desired setting by clicking on the
ON: The black image will be displayed for a camera channel that is not connected to the camera.
OFF: The camera channel will be skipped in the sequence/spot mode.
The factory default setting is ON.
99