WHEN USING A PS·DATA SYSTEM CONTROLLER

This manual describes the operating procedures which are specifically related to WJ-SX150A.

For the basic operating procedures such as log-in/log-out, camera selection, and camera control, etc., refer to the system con- troller's operating instructions.

The following are different from the terminal mode when you use the system controller via the PS·Data protocol.

Camera selection, camera control, camera site accessories control are in accordance with the PS·Data System operating procedures. Refer to the system controller's operating instructions.

You cannot reset an alarm one by one per monitor. However, you can reset all the alarms at a time (ALL RESET).

You cannot acknowledge an alarm.

You cannot use the auto log-in function of the unit. To use this function, use a terminal-mode system controller.

You cannot use the auto log-out function of the unit.

You cannot move the clock, camera title, event, and/or monitor status display with a PS·Data controller. Use a terminal- mode system controller.

Operators using the PS·Data system controller have the highest priority to all those using the terminal-mode system con- trollers.

PS·Data doesn’t support user-management, and you cannot configure the PS·Data operator registration neither through SETUP MENU nor WJ-SX150A Administrator Console.

Notes:

When you select a monitor with a PS·Data system controller, you might enter its number as you do in the terminal mode. However, the matrix switcher regards a monitor as a unit, you need to select it by the unit number. (Refer to p. 125.)

This unit is counted as 4 PS·Data units. Confirm the total number of the PS·Data units in your system. (Up to 16 PS·Data units are available.)

If you carry out an operation not designated, the PROHIBITED indicator on the system controller will light up and your oper- ation is prohibited. To cancel the prohibition, press the MON(ESC) button.

If you activate/cancel alarm suspension with a terminal-mode system controller, the system will return to the state con- trolled by PS·Data system controllers after given time.