RS-232C Adjustment Mode

3) <GST> (GET STATUS) – The status of various settings is transmitted in the following formats:

 

STX

PC SOFTWARE

INPUT FUNCTION

COLOR MODE

SCREEN SIZE

POWER SAVE

 

 

 

(02 hex)

VERSION (5 Byte)

(3 Byte)

(3 Byte)

(3 Byte)

(3 Byte) 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DUMMY DATA

COLOR SYSTEM

3D Y/C

HIGH CONTRAST

INPUT SETTING

 

 

 

 

 

(3 Byte)

(3 Byte) 2

(3 Byte) 3

(3 Byte)

(3 Byte) 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLAMP

ABL

DUMMY DATA

KEY LOCK

OSD DISPLAY

 

 

 

 

 

(3 Byte) 4

(3 Byte) 4

(3 Byte)

(3 Byte)

(3 Byte)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MIRROR MODE

CENTRAL SCREEN

FAN CONTROL

EASY TEMPERATURE

ACCUMULATED

ETX

 

 

 

(3 Byte)

BRIGHTNESS

FORMAT (3 Byte)

MEASUREMENT

ON TIME (5 Byte)

(03 hex)

 

 

 

(3 Byte) 1

(3 Byte)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(NOTE) • Items not related to the ongoing INPUT functions/INPUT signals will output dummy data.

1........ Depending on the present signal input (video or PC signal) the output content will switch.

2........ Dummy data will be output unless in INPUT 1 or 2.

3........ Dummy data will be output unless in INPUT 1.

4 ........ Dummy data will be out put unless in INPUT 3 or 4.

For more information concerning output, refer to section 5.5.4, “List of RS-232C Commands”.

Temperature

300

340

380

420

450

XXX

TxD output value (3 bytes)

 

 

 

 

 

 

 

 

 

 

 

 

 

Outside air

to 30.0

to 34.0

to 38.0

to 42.0

to 45.0

45.0 or more

temperature (°C) (see note)

 

 

 

 

 

 

 

 

 

 

 

 

 

(NOTE): The term ‘outside air temperature’ as it is used here is meant to serve as a rough guideline for when the unit has been installed so as to allow the free flow of air around the unit, and this term is therefore to be distinguished from the term ‘ambient temperature’ as used in 3 “Installation”. Note that there may be times when errors occur in temperature readings. Also note that it is particularly important to be sure to check the ambient temperature when the unit has been installed as described in 3.4 “Special Installation” to ensure that all installation requirements have been satisfied.

4) GS2 (GET STATUS 2) - Outputs the state of the various settings in the format shown below.

 

 

 

 

 

 

 

 

 

 

 

 

STX

SUB VOLUME

SUB VOLUME

SUB VOLUME

SUB VOLUME

R SIDE MASK

 

 

 

 

(02 hex)

INPUT 1 (3 Byte)

INPUT 2 (3 Byte)

INPUT 3 (3 Byte)

INPUT 4 (3 Byte)

(3 Byte)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G SIDE MASK

B SIDE MASK

DUMMY DATA

DUMMY DATA

DUMMY DATA

ETX

 

 

 

 

(3 Byte)

(3 Byte)

(3 Byte)

(3 Byte)

(3 Byte)

(03 hex)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

137

Page 137
Image 137
Pioneer 502MX technical manual Xxx, TxD output value 3 bytes, Outside air, Temperature C see note