Special Installation (Hanging on the wall)
Methods of Securing: Basic methods of securing are shown below. Avoid blocking or covering areas aside from those
indicated by . The method indicated by a large
Before attaching the unit to fittings,
(Also refer to 3.4.1 “Mounting to fittings”.)
NOTE 1
Heated air is drawn off from the interior of the unit by fans. Before installation, consider the heat resistance of the wall or other surfaces behind the unit. Exhaust temperatures can be 30 °C higher than the outside temperature.
NOTE 2
For
300 mm or |
more |
300 mm or |
more |
Flush-wall installation
(distance between unit and wall
less than 50 mm)
Requirements :
•Free air flow (With no obstructions within a distance of 300 mm from the unit)
•Temperature of
50 mm or more |
100 mm or more |
50 mm or |
more |
50 mm or |
more |
50 mm or more |
Ex.: Installation requirements when installed in recess in wall
Wall-mounted installation
(distance between unit and wall
greater than 50 mm)
Requirements :
•Free air flow (With no obstructions within a distance of 300 mm from the unit) around all four sides of the unit is not necessarily required when the unit is
installed at a distance of greater than 50 millimeters away from the wall.
*Note, however, that in such cases the unit may not be placed behind a glass panel or any other obstruction which would create
a closed space.
• Temperature of
ÉpÉìÉ`ÉìÉOÉlÉbÉgPanting net |
Ex.: Installation when covered with a Panting net
Wall-embeddedinstallation
(i.e., installation in closed space)
Requirements :
•See 3.4.3 Embedding in the wall for installation requirements..
•Temperature of
29