Special Installation (Hanging on the wall)

Methods of Securing: Basic methods of securing are shown below. Avoid blocking or covering areas aside from those

indicated by . The method indicated by a large X-mark must not be used.

Before attaching the unit to fittings, double-check that the thickness and height of the fittings, and the number of fixing bolts is correct.

(Also refer to 3.4.1 “Mounting to fittings”.)

NOTE 1

Heated air is drawn off from the interior of the unit by fans. Before installation, consider the heat resistance of the wall or other surfaces behind the unit. Exhaust temperatures can be 30 °C higher than the outside temperature.

NOTE 2

For wall-mounting, do not bundle the cables in a way that will obstruct ventilation.

300 mm or

more

300 mm or

more

Flush-wall installation

(distance between unit and wall

less than 50 mm)

Requirements :

Free air flow (With no obstructions within a distance of 300 mm from the unit)

Temperature of 0–35°C

50 mm or more

100 mm or more

50 mm or

more

50 mm or

more

50 mm or more

Ex.: Installation requirements when installed in recess in wall

Wall-mounted installation

(distance between unit and wall

greater than 50 mm)

Requirements :

Free air flow (With no obstructions within a distance of 300 mm from the unit) around all four sides of the unit is not necessarily required when the unit is

installed at a distance of greater than 50 millimeters away from the wall.

*Note, however, that in such cases the unit may not be placed behind a glass panel or any other obstruction which would create

a closed space.

• Temperature of 0–40°C

ÉpÉìÉ`ÉìÉOÉlÉbÉgPanting net

Ex.: Installation when covered with a Panting net

Wall-embeddedinstallation

(i.e., installation in closed space)

Requirements :

See 3.4.3 Embedding in the wall for installation requirements..

Temperature of 0–40°C

29

Page 29
Image 29