Special Installation (Mounting to fittings)

3.4 Special Installation

The unit can be hung from or embedded in a wall, but such special installations impose additional limitations on operating temperatures and other operational factors.

Examine installation methods and the ambient conditions for your installation site, and refer to sections 3.1 to 3.3 in this manual.

Measurements discussed in this manual assume the following conditions:

A 100 % white input is supplied.

Sufficient aging has been completed.

Make all measurements under identical conditions. The aging period required for correct measurement will be about two and a half hours, depending on the space available at the installation site.

3.4.1 Mounting to fittings

Observe the following guidelines when mounting the unit to fittings.

Notes 2 to 7 apply to all cases of mounting to fitting.

1When mounting the unit, make sure that there are no objects around it within a distance of 300mm.

2Any unit deformation/warping occurring as a result of installation should be less than 4 mm.

3Never block or cover openings, aside from those shown as blocked in the illustrations on the following page.

4The fittings should have a thickness of less than 20 mm. (This limit does not apply to fittings in examples 2, 4, 6 and 8 on the following page.)

5L-shaped fittings should have a thickness of less than 100 mm.

6The strength of the fittings should be adequate to bear the weight of the display.

7Take precautions to avoid sharply bending the power cable.

4 mm MAX

Less than 100 mm

Maximum allowable deformation/warping is 4 mm.

Arrange the power cable so that minimum stress is placed on it.

Less than

20 mm

L-shaped fitting

Less than

20 mm

No thickness limitations in examples 2, 4, 6 and 8 on the following page.)

No thickness limitations in examples 2, 4, 6 and 8 on the following page.)

Operating environment for standard installation

• Ambient Temperature: 0 to 40 °C (examples 1 to 4)

Operating environment for vertical installation

0 to 40 °C (vertical installation: examples 5 to 8)

Operating temperatures for Upside-Down Installations (possible only for attachment examples 2 and 3)

• Ambient temperature: 0 to 40 °C

The operating temperature restrictions for the speaker system (PDP-S03-LR) are the same regardless of whether installation is horizontal or vertical.

26

Page 26
Image 26
Pioneer 502MX technical manual Special Installation Mounting to fittings, Operating environment for standard installation