Administrator’s Guide for the VSX Series

Symptom

Problem

Corrective action

 

 

 

The camera does not track

The room setup interferes

Consider room treatments that provide acoustic

to the person who is

with voice tracking. Large

damping, such as carpeting and curtains.

speaking.

windows, uncarpeted

Ensure that the camera has at least 3 ft (1 m)

Automatic camera tracking

floors, and the way the unit

clearance above, behind, and to each side.

is mounted on a wall or

is available only on a

Verify that the room is small enough for automatic

alcove can interfere with

VSX 7000e or VSX 8000

camera tracking to work properly. Polycom

voice tracking.

system with a Polycom

recommends that you use this feature only if the

 

PowerCam Plus camera.

 

 

room is 20 x 25 x 9 feet (6.1 x 7.6 x 2.7 m) or smaller.

(Continued)

 

 

 

 

 

 

One site cannot control the

Far-site camera control is

Ask the participants at the far site to aim the camera.

other site’s camera.

not enabled.

 

 

 

 

 

One of the systems does

Ask the participants at the far site to aim the camera.

 

not have the far-site

 

 

camera control capability.

 

 

 

 

7 - 22

Page 194
Image 194
Polycom VSX Series manual Symptom Problem Corrective action