Diagnostics and General Troubleshooting

 

 

 

Power and Start-up

 

 

 

 

 

Symptom

Problem

Corrective action

 

 

 

The system does not start

The power switch is off.

Turn on the power switches for the system and all

or respond in any way.

Note: VSX 3000 and

equipment connected to it.

 

VSX 3000A systems have

 

 

three power switches.

 

 

 

 

 

The power cord is not

VSX 3000, VSX 3000A, VSX 5000, VSX 6000,

 

connected.

VSX 6000A:

 

 

Make sure the power pack is connected to a power

 

 

outlet, and that its power cords are seated securely.

 

 

VSX 7000, VSX 7000s:

 

 

Make sure that the system is connected to the

 

 

subwoofer and that the subwoofer is connected to a

 

 

power outlet. The power for the system is supplied by

 

 

the subwoofer, so it must be connected in order for

 

 

the system to work.

 

 

VSX 7000e, VSX 8000:

 

 

Make sure that the system’s power cord is in place,

 

 

and that it is connected to a power outlet.

 

 

 

 

The power outlet is not

If you connect the system’s power cord to a power

 

active, or the system’s

strip, be sure the power strip is connected to a power

 

power supply is not

outlet and its power switch is on.

 

operating properly.

Check the power outlet by unplugging the system

 

 

and plugging in a lamp, radio, or other small

 

 

appliance. If it does not operate, the outlet is not

 

 

active — connect the system to a different outlet.

 

 

If the outlet is active, the problem could be in the

 

 

system’s power supply. In this case, call Polycom

 

 

Technical Support and arrange to return the system

 

 

for service.

 

 

 

The system starts in the

The power switch was

To power up the system, press and release the

software update screen.

pressed for too long.

power button.

 

(VSX 7000e, VSX 8000)

 

 

This is normal.

 

 

 

 

 

The system software is

Load the system software from your computer. For

 

corrupted or not loaded

instructions on how to do this, refer to Keeping your

 

properly.

Software Current on page 3-34.

 

 

 

The system restarts over

The power plug is not fully

Make sure the power plug is seated securely.

and over.

seated.

 

 

 

 

 

The socket is corroded.

Unplug and reseat the power plug 5 times.

 

 

 

 

The power plug is damaged

Call service for an RMA to return the defective part.

 

or the power supply is bad.

 

 

 

 

7 - 9

Page 181
Image 181