14.Press Enter and the following screen displays:
Processor Conversion
Step A: After changing the processor, you should initialize the new processor by running Program
Step B: From the Programming Telephone, use Program 03 to set code 41 for the cabinet slot that contains the new TTY/Maintenance PIOU, PIOUS, or RSSU PCB and proceed to Step D. If you added an RSIU/ RSIS/RMDS PCB, set code 49 for cabinet slot 11 and proceed to Step C.
Step C: From the Programming Telephone, use Program
Step D: Turn DK off (5 sec) then on. From the Programming Telephone, test the RCTU (R3) RAM by running Program
Press any key to Continue
15.Press Enter (twice) after completing the Steps above. The Baud Rate Selection screen displays (shown below). This screen enables you to set the DKAdmin/DKBackup PC COM port baud rate which must match the baud rate of the TTY port set by the programming telephone in Program 76 (if upgrading TTY port to RSIU).
Baud Rate Selection
Please adjust the baud rate of DKBackup PC COM port to match the new PIOU, PIOUS, RSSU or RSIU/RSIS you may have installed.
Baud Rate | 300 |
9600 | 1200 |
| |
| 2400 |
| 4800 |
| 9600 |
| 14400 |
| 19200 |
| 38400 |
| 57600 |
|
|
Note This Step enables you to switch the TTY port from a PIOU (1200 bps) to an RSIU (9600 bps) TTY port to complete the upgrade process faster.
Backup Menu (DKBackup) | 111 |