––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Upgrade

14.Press Enter and the following screen displays:

Processor Conversion

Step A: After changing the processor, you should initialize the new processor by running Program 91-9 manually from the Programming Telephone. Then you must reset the PIOU, PIOUS, RSSU, or RSIU/ RSIS/RMDS TTY port that is connected to DKAdmin PC by performing Step B and/or C.

Step B: From the Programming Telephone, use Program 03 to set code 41 for the cabinet slot that contains the new TTY/Maintenance PIOU, PIOUS, or RSSU PCB and proceed to Step D. If you added an RSIU/ RSIS/RMDS PCB, set code 49 for cabinet slot 11 and proceed to Step C.

Step C: From the Programming Telephone, use Program 76-1 and 76-2 to set the RSIU/RSIS/RMDS ports for their appropriate functions and baud rates. DKAdmin will pull Program 76 and adjust the DKAdmin customer database accordingly. Make sure the TTY/Maintenance port settings are correct to insure a successful Upgrade process. Proceed to Step D.

Step D: Turn DK off (5 sec) then on. From the Programming Telephone, test the RCTU (R3) RAM by running Program 00-(51,52/61, 62)

Press any key to Continue

15.Press Enter (twice) after completing the Steps above. The Baud Rate Selection screen displays (shown below). This screen enables you to set the DKAdmin/DKBackup PC COM port baud rate which must match the baud rate of the TTY port set by the programming telephone in Program 76 (if upgrading TTY port to RSIU).

Baud Rate Selection

Please adjust the baud rate of DKBackup PC COM port to match the new PIOU, PIOUS, RSSU or RSIU/RSIS you may have installed.

Baud Rate

300

9600

1200

 

 

2400

 

4800

 

9600

 

14400

 

19200

 

38400

 

57600

 

 

Note This Step enables you to switch the TTY port from a PIOU (1200 bps) to an RSIU (9600 bps) TTY port to complete the upgrade process faster.

Backup Menu (DKBackup)

111

Page 121
Image 121
Toshiba DK Backup, DK Admin manual 111