DK424 Release 4.0 Upgrade Programming Ex ample –––––––––––––––––––––––––––––––––––––––––––––––––––
158 DKAdmin/DKBackup
Programs *04, 05, 09
There is no change to the data in these programs when upgrading to Release 4.0. Note that
DID/Tie ports do not cause Phantom DN ports to shift in Strata DK Release 1~Release 3
systems, so they do not shift in Program *04 when upgrading to Release 4.0. Also, the data in
Program 09 is DN numbers and not port numbers, so data in Program 09 does not change
when upgrading to Release 4.0.
Program *09
Data in this program must be changed to adjust for port shifting caused by the RDDU DID l ine
PCB in slot 13 (see Figures 33 and 34):
Programs 10-1 through 10-4
There is no change to the data in these system programs when upgrading to Release 4.0. Port
numbers are not assigned to system programs so no adjustments are necessary.
Program 13
If the Message Center is the Front Office Telephone (PDN 112), data in this program must be
changed to adjust for port shifting caused by the RDDU DID line PCB in slot 13 (see Figures
33 and 34):
Data for Program 13 before the upgrade = 012
Data for Program 13 after the upgrade = 008
If the Message Center is the Lobby Telephone (PDN 100), data in this program must not be
changed to adjust for port shifting caused by the RDDU DID line PCB in slot 13. This is
because Port 000 did not shift after the upgrade (see Figures 33 and 34):
Data for Program 13 before the upgrade = 000
Data for Program 13 after the upgrade = 000
Programs 15, 16, and 17
There is no change to the data in these programs when upgrading to Release 4.0. These are CO
line programs and port numbers are not assigned in them so no adjustments are necessary.
Program *17
If the DID Intercept Destination is the Back Room Telephone (PDN 119), data in this program
must be changed to adjust for port shifting caused by the RDDU DID line PCB in slot 13 (see
Figures 33 and 34):
Program *17 data for DID lines 001~004 before the upgrade = 019
Program *17 data for DID lines 001~004 after the upgrade = 015
Before the Upgrade After the Upgrade
Port 000-007; Data 100-107 Port 000-007; Data 100-107
Port 008-015; Data 108-115 Port 008-015; Data 112-119
Port 016-019; Data 116-119 Port 016-019; Data Blank