–––––––––––––––––––––––––––––––––––––––Important Things to Do After Upgrading to an RCTUE/F Processor

processor, remove the MBJU from DK424 Base Cabinet per Chapter 5 – DK424 Installation in the Strata I/M Manual, and install the RCTUE/F processor).

8.From the programming telephone run Program 91-9 (twice) to initialize the RCTU E/F processor.

9.From the programming telephone run Programs 03, 76, and 77-1 to set up the TTY interface port.

10.Turn system power off for five seconds then turn power back on.

11.Continue the upgrade by following the DKAdmin prompts.

12.After DKAdmin upgrades and uploads the customer database, it prompts you to “Perform Automatic Power OFF/ON”; answer Yes. DKAdmin runs Program 91-2, then prompts you to receive data to complete the upgrade process; answer Yes. DKAdmin downloads the upgraded RCTUE/F database and builds the customer file.

The upgrade is now complete.

Important Things to Do After Upgrading to an RCTUE/F Processor

Using DKAdmin, run Program *03 to identify DK424 cabinets.

If installing line and/or station PCBs in slots 07 and 08 of a DK424 expansion cabinet, circuit line and port numbers in slots that follow will shift. It is recommended you move the appropriate station and line cables back to the new installed PCBs. This insures that telephone and line programs match the physical ports and lines.

Do not try to swap or relocate ports in Program 01 or 02 to match port programming to physical connections.

When using an RCTUE/F processor in a DK424 Base Cabinet, you must remove the MBJU from between the R11 and RCTU slot of the DK424 Base Cabinet.

In the above configuration, only DK424 Expansion Cabinets provide eight universal PCB slots (S_1 to S_8). DK280 Expansion Cabinets only provide six universal slots (S_1 to S_6) in this or any other configuration of RCTU processor and Base Cabinet (see the Strata I&M Manual for more configuration details).

ACD overflow assignment codes in Programs 14-4, 14-5, and 14-6 have been upgraded to the new codes in the RCTUE/F.

Station speed dial codes *10-*49 have been upgraded to the new RCTUE/F codes *100- *139, respectively, in REPALL and Programs 29, *29, 39, and 59.

ACD and IMDU/RMDS port numbers have been upgraded to the new RCTUE/F codes in Programs *09 and 71.

DK424 RCTUE/F Upgrade Using DKAdmin

147

Page 157
Image 157
Toshiba DK Backup, DK Admin manual 147