DK424 Release 4.0 Upgrade Programming Example –––––––––––––––––––––––––––––––––––––––––––––––––––

DK424 Release 4.0 Upgrade Programming Example

Important! When upgrading to DK424 Release 4.0 from a lower release, it is highly recommended to use the DKAdmin or DKBackup Release 4.0 PC software program. Trying to upgrade to Release 4.0 manually from the programming telephone could take many hours.

The following Release 3.0 to Release 4.0 upgrade example demonstrates some basic programming changes automatically performed by DKAdmin due to station port shifting. Station port shifting only occurs when station PCBs are in higher numbered slots than Tie and/ or DID lines.

This example does not give you every program change required, nor does it attempt to instruct you on how to re-program a system upgraded to Release 4.0, using the programming telephone. This is a simple system upgrade; an actual installed systems can be much more complex to upgrade.

Cabinet Station Port Counting Before/After Release 4.0 Upgrade

Figures 31 shows the DKAdmin cabinet drawing of a DK424 system with an:

RCTUE3/F3 processor

RSIU interface

16 Digital telephones

4 analog DID lines

Notice that the RDDU PCB increments the station ports by four ports.

PCB Placement per Program 03

Cabinet 1

R11

RCTU

S11

S12

S13

S14

S15

S16

PCB Type

RCTUE3

RCTUF3

RSIU

PDKU2

RDDU

PDKU2

 

 

Port Nos.

 

 

 

000~007

008~011

012~019

 

 

Line Nos.

 

 

 

 

001~004

 

 

 

Option/Note

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 31 Cabinet Drawing for RCTUE3/F3 Before Release 4 Upgrade

Figure 32 shows the same DKAdmin cabinet drawing after upgrading to an RCTUE3/F4 with DKAdmin.

Notice that the telephones connected to the PDKU2 in slot 14 were on ports 012~019 but are now on ports 008~015, respectively. This phenomenon requires many programming changes to enable the DK system to operate the same as it did prior to the upgrade. DKAdmin/

DK Backup Release 4.0 is designed to make all programming changes automatically to enable the upgrade to be transparent to the system operation.

PCB Placement per Program 03

Cabinet 1

R11

RCTU

S11

S12

S13

S14

S15

S16

PCB Type

RCTUE3

RCTUF4

RSIU

PDKU2

RDDU

PDKU2

 

 

Port Nos.

 

 

 

000~007

 

008~015

 

 

Line Nos.

 

 

 

 

001~004

 

 

 

Option/Note

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 32 Cabinet Drawing for RCTUE3/F4 After Release 4 Upgrade

154

DKAdmin/DKBackup

Page 164
Image 164
Toshiba DK Admin, DK Backup manual DK424 Release 4.0 Upgrade Programming Example, 154