280 Technical data
ElectricalElectrical specifications 210 to 246 VAC
Voltage
Scanner 120 VAC
Printer Single phase 214 to 250 VAC
Three phase 185 to 215 VAC
Current (Amps)
Scanner 20 A
Printer 30 A
Power consumption (Watts) Scanner Printer
Running 1100 5800
Standby 1000 5100
Environmental dataOperating range
Relative humidity 15% to 85%
Temperature 500 F to 900 F
Heat output
Running 11,068 BTU/hr.
Standby 2700 BTU/hr.
Audible noise (scanner and printer)
Running 49.5 db (A) or less
Standby 64 db (A) continuous
72 db (A) maximum
Ozone
Concentration based on simulation model:
Daily copy volume: 8250 copies/8 hours
Room size: 17 m3
0 Air changes per hour
77.6 ug/min
0.009 ppm (time weighted average)
0.016 ppm (peak) threshold limit value (0.10
ppm)
Total dust
0.04 mg/m3threshold limit value (10
mg/m3)
Organics
<10ppb