Parameter Description | Issue 01/06 |
P1300 = 19 : V/f control with independent voltage setpoint
The following table presents an overview of control parameters (V/f) that can be modify in relationship to
P1300 dependencies:
ParNo. | Parameter name | Level |
|
|
|
| V/f |
|
|
|
|
|
| SLVC | VC | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| P1300 = |
|
|
|
|
|
| ||
|
|
| 0 | 1 | 2 | 3 |
|
| 5 |
| 6 | 19 | 20 |
| 22 | 21 |
| 23 | |
P1300[3] | Control mode | 2 | x | x | x |
| x |
|
| x |
| x | x | x |
| x | x |
| x |
P1310[3] | Continuous boost | 2 | x | x | x |
| x |
|
| x |
| x | x | − |
| − | − |
| − |
P1311[3] | Acceleration boost | 2 | x | x | x |
| x |
|
| x |
| x | x | − |
| − | − |
| − |
P1312[3] | Starting boost | 2 | x | x | x |
| x |
|
| x |
| x | x | − |
| − | − |
| − |
P1316[3] | Boost end frequency | 3 | x | x | x |
| x |
|
| x |
| x | x | − |
| − | − |
| − |
P1320[3] | Programmable V/f freq. coord. 1 | 3 | − | − | − |
| x |
|
| − |
| − | − | − | − | − | − |
|
|
P1321[3] | Programmable V/f volt. coord. 1 | 3 | − | − | − |
| x |
|
| − |
| − | − | − | − | − | − |
|
|
P1322[3] | Programmable V/f freq. coord. 2 | 3 | − | − | − |
| x |
|
| − |
| − | − | − | − | − | − |
|
|
P1323[3] | Programmable V/f volt. coord. 2 | 3 | − | − | − |
| x |
|
| − |
| − | − | − | − | − | − |
|
|
P1324[3] | Programmable V/f freq. coord. 3 | 3 | − | − | − |
| x |
|
| − |
| − | − | − | − | − | − |
|
|
P1325[3] | Programmable V/f volt. coord. 3 | 3 | − | − | − |
| x |
|
| − |
| − | − | − | − | − | − |
|
|
P1330[3] | CI: Voltage setpoint | 3 | − | − | − | − | − |
|
| − |
| x | − |
| − | − |
| − | |
P1333[3] | Start frequency for FCC | 3 | − | x | − |
| − |
| − |
|
| x | − | − |
| − |
| − |
|
P1335[3] | Slip compensation | 2 | x | x | x |
| x |
|
| − |
| − | − | − | − | − | − |
|
|
P1336[3] | CO: U/f Slip limit | 2 | x | x | x |
| x |
|
| − |
| − | − | − | − | − | − |
|
|
P1338[3] | Resonance damping gain V/f | 3 | x | x | x |
| x |
|
| − |
| − | − | − | − | − | − |
|
|
P1340[3] | Imax freq. controller prop. gain | 3 | x | x | x |
| x |
|
| x |
| x | x | − |
| − | − |
| − |
P1341[3] | Imax controller integral time | 3 | x | x | x |
| x |
|
| x |
| x | x | − |
| − | − |
| − |
P1345[3] | Imax controller prop. gain | 3 | x | x | x |
| x |
|
| x |
| x | x | − |
| − | − |
| − |
P1346[3] | Imax voltage ctrl. integral time | 3 | x | x | x |
| x |
|
| x |
| x | x | − |
| − | − |
| − |
P1350[3] | Voltage soft start | 3 | x | x | x |
| x |
|
| x |
| x | x | − |
| − | − |
| − |
SLVC / VC can provide excellent performance for the following types of application:
-Applications which require high torque performance
-Applications which require fast respond to shock loading
-Applications which require torque holding while passing through 0 Hz
-Applications which require very accurate speed holding
-Applications which require motor pull out protection
-SLVC / VC is dependent on the accuracy of the motor model being used and the measurements being performed by the inverter. There are therefore certain restrictions on the use of SLVC / VC:
fmax = min(200 Hz, 5 P0310) | (max. frequency) | ||||||
| 1 | ≤ | P0305 | ≤ | r0209 | (ratio of rated motor current to rated inverter current) | |
4 | r0207 | r0207 | |||||
|
|
|
no synchronuos motor
Recommended means of
-For correct operation under SLVC / VC control it is imperative that the name plate data of the motor (P0304 - P0310) is correctly entered and that the motor data identification (P1910) must be carried out on a cold motor. It is also necessary to ensure that the motor ambient temperature is correctly entered in P0625 if this is significantly different from the default value of 20°C. This must be done after the quick commissioning has been completed (P3900) but before the motor data identification measurements are carried out.
-See parameter P0400 and documentation of encoder and encoder module when commissioning VC (P1300 = 21 or 23).
The following parameters can be adjusted by the user to improve performance. - P0003 = 3
| - P0342: Total / motor inertia ratio |
| Sensorless Vector Control (SLVC): |
| - P1470: P gain (SLVC) |
| - P1472: I term (SLVC) |
| - P1610: Continuous torque boost (SLVC, open loop boost) |
| - P1611: Acceleration torque boost (SLVC, open loop boost) |
| - P1750: Control word of motor model |
| - P1755: |
154 | MICROMASTER 440 Parameter List |