Parameter Description |
|
|
|
| Issue 01/06 | |||
|
|
|
|
|
| |||
P0702[3] Function of digital input 2 |
| Min: | 0 |
| Level | |||
| CStat: | CT | Datatype: U16 | Unit: - | Def: | 12 |
| 2 |
|
|
| ||||||
| COMMANDS | Active: first confirm | QuickComm.: No | Max: | 99 |
|
|
Selects function of digital input 2.
Possible Settings:
0 | Digital input disabled | |
1 | ON/OFF1 | |
2 | ON reverse /OFF1 | |
3 | OFF2 | - coast to standstill |
4 | OFF3 | - quick |
9 | Fault acknowledge | |
10 | JOG right | |
11 | JOG left |
|
12 | Reverse | |
13 | MOP up | (increase frequency) |
14 | MOP down (decrease frequency) | |
15 | Fixed setpoint (Direct selection) | |
16 | Fixed setpoint (Direct selection + ON) | |
17 | Fixed setpoint (Binary coded selection + ON) | |
25 | DC brake enable | |
29 | External trip | |
33 | Disable additional freq setpoint | |
99 | Enable BICO parameterization | |
Index: |
|
|
P0702[0] : 1st. Command data set (CDS) | ||
P0702[1] : 2nd. Command data set (CDS) | ||
P0702[2] : 3rd. Command data set (CDS) | ||
Details: |
|
|
See P0701 (function of digital input1). |
P0703[3] Function of digital input 3 |
| Min: | 0 | Level | |||
| CStat: | CT | Datatype: U16 | Unit: - | Def: | 9 | 2 |
| COMMANDS | Active: first confirm | QuickComm.: No | Max: | 99 |
|
Selects function of digital input 3.
Possible Settings:
0Digital input disabled
1ON/OFF1
2ON reverse /OFF1
3 | OFF2 - coast to standstill |
4OFF3 - quick
9Fault acknowledge
10JOG right
11JOG left
12Reverse
13MOP up (increase frequency)
14MOP down (decrease frequency)
15Fixed setpoint (Direct selection)
16Fixed setpoint (Direct selection + ON)
17Fixed setpoint (Binary coded selection + ON)
25DC brake enable
29External trip
33Disable additional freq setpoint
99Enable BICO parameterization
Index:
P0703[0] : 1st. Command data set (CDS)
P0703[1] : 2nd. Command data set (CDS)
P0703[2] : 3rd. Command data set (CDS)
Details:
See P0701 (function of digital input 1).
78 | MICROMASTER 440 Parameter List |