Issue 01/06 | Parameter Description |
r2033 | BO: CtrlWrd2 from BOP link (USS) |
| Min: | - |
| Datatype: U16 | Unit: - | Def: | - |
|
| Max: | - |
Displays control word 2 from BOP link (i.e. word 4 within USS).
Bitfields: |
|
|
|
|
|
Bit00 | Fixed frequency Bit 0 | 0 | NO | 1 | YES |
Bit01 | Fixed frequency Bit 1 | 0 | NO | 1 | YES |
Bit02 | Fixed frequency Bit 2 | 0 | NO | 1 | YES |
Bit03 | Fixed frequency Bit 3 | 0 | NO | 1 | YES |
Bit04 | Drive data set (DDS) Bit 0 | 0 | NO | 1 | YES |
Bit05 | Drive data set (DDS) Bit 1 | 0 | NO | 1 | YES |
Bit08 | PID enabled | 0 | NO | 1 | YES |
Bit09 | DC brake enabled | 0 | NO | 1 | YES |
Bit11 | Droop enabled | 0 | NO | 1 | YES |
Bit12 | Torque control | 0 | NO | 1 | YES |
Bit13 | External fault 1 | 0 | YES | 1 | NO |
Bit15 | Command data set (CDS) Bit 1 | 0 | NO | 1 | YES |
Dependency: |
|
|
|
|
|
P0700 = 4 (USS on BOP link) and P0719 = 0 (Cmd / Setpoint = BICO parameter).
Level
3
r2036 | BO: CtrlWrd1 from COM link (USS) |
| Min: | - | Level |
| Datatype: U16 | Unit: - | Def: | - | 3 |
|
| ||||
|
| Max: | - |
|
Displays control word 1 from COM link (i.e. word 1 within USS).
| Bitfields: |
|
|
|
|
|
|
| |
|
| Bit00 | ON/OFF1 |
| 0 | NO | 1 | YES | |
|
| Bit01 | OFF2: Electrical stop |
| 0 | YES | 1 | NO | |
|
| Bit02 | OFF3: Fast stop |
| 0 | YES | 1 | NO | |
|
| Bit03 | Pulses enabled |
| 0 | NO | 1 | YES | |
|
| Bit04 | RFG enable |
| 0 | NO | 1 | YES | |
|
| Bit05 | RFG start |
| 0 | NO | 1 | YES | |
|
| Bit06 | Setpoint enable |
| 0 | NO | 1 | YES | |
|
| Bit07 | Fault acknowledge |
| 0 | NO | 1 | YES | |
|
| Bit08 | JOG right |
| 0 | NO | 1 | YES | |
|
| Bit09 | JOG left |
| 0 | NO | 1 | YES | |
|
| Bit10 | Control from PLC |
| 0 | NO | 1 | YES | |
|
| Bit11 | Reverse (setpoint inversion) |
| 0 | NO | 1 | YES | |
|
| Bit13 | Motor potentiometer MOP up |
| 0 | NO | 1 | YES | |
|
| Bit14 | Motor potentiometer MOP down |
| 0 | NO | 1 | YES | |
|
| Bit15 | CDS Bit 0 (Local/Remote) |
| 0 | NO | 1 | YES | |
| Details: |
|
|
|
|
|
|
| |
|
| See r2033 (control word 2 from BOP link). |
|
|
|
|
|
| |
r2037 |
| BO: CtrlWrd2 from COM link (USS) |
|
| Min: | - |
| Level | |
|
|
| Datatype: U16 | Unit: - |
| Def: | - |
| 3 |
|
| COMM |
|
| Max: | - |
| ||
|
|
|
|
|
| ||||
|
| Displays control word 2 from COM link (i.e. word 4 within USS). |
|
|
|
|
| ||
| Bitfields: |
|
|
|
|
|
|
| |
|
| Bit00 | Fixed frequency Bit 0 |
| 0 | NO | 1 | YES | |
|
| Bit01 | Fixed frequency Bit 1 |
| 0 | NO | 1 | YES | |
|
| Bit02 | Fixed frequency Bit 2 |
| 0 | NO | 1 | YES | |
|
| Bit03 | Fixed frequency Bit 3 |
| 0 | NO | 1 | YES | |
|
| Bit04 | Drive data set (DDS) Bit 0 |
| 0 | NO | 1 | YES | |
|
| Bit05 | Drive data set (DDS) Bit 1 |
| 0 | NO | 1 | YES | |
|
| Bit08 | PID enabled |
| 0 | NO | 1 | YES | |
|
| Bit09 | DC brake enabled |
| 0 | NO | 1 | YES | |
|
| Bit11 | Droop enabled |
| 0 | NO | 1 | YES | |
|
| Bit12 | Torque control |
| 0 | NO | 1 | YES | |
|
| Bit13 | External fault 1 |
| 0 | YES | 1 | NO | |
|
| Bit15 | Command data set (CDS) Bit 1 |
| 0 | NO | 1 | YES | |
| Details: |
|
|
|
|
|
|
|
See r2033 (control word 2 from BOP link).
MICROMASTER 440 | Parameter List |
203 |