Issue 01/06 | Parameter Description |
r0031 | CO: Act. filtered torque |
| Min: | - |
| Datatype: Float | Unit: Nm | Def: | - |
|
|
| Max: | - |
Displays electrical torque.
Level
2
mM = | 3 | ⋅ | Lm | ⋅ Zp ⋅ Ψ rd ⋅ isq | |
2 | LR | ||||
|
|
|
Valid for
isq ≈ | u ⋅ is ⋅ cosϕ − | Rs2 ⋅ is |
e |
| |
|
|
mM : Motor torque
Zp : Pole pair number
Ψrd : Rotor flux
LR : Rotor inductance
Lm : Magnetizing inductance
isq :
Output value will be zero at low speeds when the current injection is active (r1751.5 = 1).
Note:
The electrical torque is not the same as the mechanical torque, which can be measured on the shaft. Due to windage and friction a part of the electrical torque is lost in the motor.
r0032 | CO: Act. filtered power |
| Min: | - |
| Datatype: Float | Unit: - | Def: | - |
|
|
| Max: | - |
Displays motor power (power output at the motor shaft).
Level
2
|
| Pmech = ω ⋅ M = | 2 ⋅ π | ⋅ f ⋅ M |
|
| ||
| ω , M | ⇒ | 1 |
|
| r0022 |
| |
| r0032[kW ]= |
|
| ⋅ 2 ⋅ π ⋅ | [1/min]⋅ r0031[Nm] | |||
Motor |
|
|
| |||||
|
| 1000 | 60 | |||||
|
|
|
|
|
|
r0032[hp] = 0.75 ⋅ r0032[kW]
Dependency:
Value is displayed in [kW] or [hp] depending on setting for P0100 (operation for Europe / North America).
r0035[3] | CO: Act. motor temperature |
| Min: | - |
| Datatype: Float | Unit: °C | Def: | - |
|
| Max: | - | |
Index: | Displays measured motor temperature. |
|
|
|
|
|
|
|
Level
2
r0035[0] : 1st. Drive data set (DDS)
r0035[1] : 2nd. Drive data set (DDS)
r0035[2] : 3rd. Drive data set (DDS)