Issue 01/06 | Parameter Description |
3.9Digital inputs
P0701[3] Function of digital input 1 |
| Min: | 0 | ||
CStat: | CT | Datatype: U16 | Unit: - | Def: | 1 |
COMMANDS | Active: first confirm | QuickComm.: No | Max: | 99 |
Selects function of digital input 1.
DIN channel(e.g. DIN1 - PNP (P0725 = 1))
Level
2
Kl.9 | PNP/NPN DIN |
P24 (PNP) | 0 ... 1 |
Kl.28 | P0725 (1) |
0 V (NPN) |
|
Debounce time: DIN
P0701
24 |
V |
0 | 0 | 24 V |
1 | 1 |
|
0 ... | 3 |
|
| |
P0724 (3) | ||||
|
|
|
|
|
| T | 0 |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
&
Function
r0722 Pxxxx BI : ...
r0722 .0 CO/BO: Bin.inp.val
0 V
Possible Settings:
0Digital input disabled
1ON/OFF1
2ON reverse /OFF1
3 | OFF2 - coast to standstill |
4OFF3 - quick
9Fault acknowledge
10JOG right
11JOG left
12Reverse
13MOP up (increase frequency)
14MOP down (decrease frequency)
15Fixed setpoint (Direct selection)
16Fixed setpoint (Direct selection + ON)
17Fixed setpoint (Binary coded selection + ON)
25DC brake enable
29External trip
33Disable additional freq setpoint
99Enable BICO parameterization
Index:
P0701[0] : 1st. Command data set (CDS)
P0701[1] : 2nd. Command data set (CDS)
P0701[2] : 3rd. Command data set (CDS)
Dependency:
Setting 99 (enable BICO parameterization) requires
-P0700 command source or
-P0010 = 1, P3900 = 1, 2 or 3 quick commissioning or
-P0010 = 30, P0970 = 1 factory reset in order to reset.
Notice:
Setting 99 (BICO) for expert use only.
MICROMASTER 440 | Parameter List |