292
BI: Inh. neg. setp
P1110.C
(0:0)
|
|
|
| Skip frequency 2 |
| Skip frequency 4 | ||||||||
|
|
| 0.00 ... 650.00 [Hz] | 0.00 ... 650.00 [Hz] | ||||||||||
|
|
|
| P1092.D (0.00) |
| P1094.D (0.00) | ||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||
Skip frequency 1 |
| Skip frequency 3 |
|
|
| |||||||||
0.00 ... 650.00 [Hz] | 0.00 ... 650.00 [Hz] |
|
| Max. frequency | ||||||||||
P1091.D (0.00) |
| P1093.D (0.00) |
|
| ||||||||||
|
| 0.00 ... 650.00 [Hz] | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| P1082.D (50.00) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Function Diagrams
JOG
| SUM or |
| SUM/JOG |
| PID controller |
| selection |
|
|
|
|
BI: Reverse
P1113.C
(722:1)
0
No evaluation with PID
r1079
CO: Sel. freq.setp
1
0
fOUT
Bandwidth
Skip frequency
fIN
r1114
0.00... 10.00 [Hz] P1101.D (2.00)
Resultant max freq [Hz]
r1084
y
x | RFG |
| |
| r1119 |
CO:Setp before RFG
Min. frequency
0.00... 650.00 [Hz] P1080.D (0.00)
MICROMASTER 440 Parameter List
1 | 2 |
| 3 | 4 | 5 | 6 | 7 |
| 8 |
Setpoint channel |
|
|
|
|
| 5200_AFM.vsd | Function diagram |
| - 5200 - |
Additional Frequency Modifications (AFM) |
|
|
| 16.01.2006 V2.1 | MICROMASTER 440 | ||||
|
|
|
|