Issue 01/06 | Parameter Description |
P0364[3] Magnetizing curve flux 3 |
| Min: | 0.0 | ||
CStat: | CUT | Datatype: Float | Unit: % | Def: | 115.0 |
MOTOR | Active: Immediately | QuickComm.: No | Max: | 300.0 |
Level
4
Specifies third flux value of saturation characteristic in [%] relative to rated motor voltage (P0304).
Index:
P0364[0] : 1st. Drive data set (DDS)
P0364[1] : 2nd. Drive data set (DDS)
P0364[2] : 3rd. Drive data set (DDS)
Details:
See P0362 (magnetizing curve flux 1).
P0365[3] Magnetizing curve flux 4 |
| Min: | 0.0 | Level | |||
| CStat: | CUT | Datatype: Float | Unit: % | Def: | 125.0 | 4 |
|
| ||||||
| MOTOR | Active: Immediately | QuickComm.: No | Max: | 300.0 |
|
Specifies fourth flux value of saturation characteristic in [%] relative to rated motor voltage (P0304).
Index:
P0365[0] : 1st. Drive data set (DDS)
P0365[1] : 2nd. Drive data set (DDS)
P0365[2] : 3rd. Drive data set (DDS)
Details:
See P0362 (magnetizing curve flux 1).
P0366[3] Magnetizing curve imag 1 |
| Min: | 0.0 | Level | |||
| CStat: | CUT | Datatype: Float | Unit: % | Def: | 50.0 | 4 |
| MOTOR | Active: Immediately | QuickComm.: No | Max: | 500.0 |
|
Specifies first magnetizing current value of the saturation characteristic in [%] relative to the rated magnetizing current (P0331).
Index:
P0366[0] : 1st. Drive data set (DDS)
P0366[1] : 2nd. Drive data set (DDS)
P0366[2] : 3rd. Drive data set (DDS)
Dependency:
Affects P0320 (motor magnetizing current).
Details:
See P0362 (magnetizing curve flux 1).
P0367[3] Magnetizing curve imag 2 |
| Min: | 0.0 | Level | |||
| CStat: | CUT | Datatype: Float | Unit: % | Def: | 75.0 | 4 |
| MOTOR | Active: Immediately | QuickComm.: No | Max: | 500.0 |
|
Specifies second magnetizing current value of saturation characteristic in [%] relative to rated magnetizing current (P0331).
Index:
P0367[0] : 1st. Drive data set (DDS)
P0367[1] : 2nd. Drive data set (DDS)
P0367[2] : 3rd. Drive data set (DDS)
Dependency:
Affects P0320 (motor magnetizing current).
Details:
See P0362 (magnetizing curve flux 1).
P0368[3] Magnetizing curve imag 3 |
| Min: | 0.0 | Level | |||
| CStat: | CUT | Datatype: Float | Unit: % | Def: | 135.0 | 4 |
|
| ||||||
| MOTOR | Active: Immediately | QuickComm.: No | Max: | 500.0 |
|
Specifies third magnetizing current value of saturation characteristic in [%] relative to rated magnetizing current (P0331).
Index:
P0368[0] : 1st. Drive data set (DDS)
P0368[1] : 2nd. Drive data set (DDS)
P0368[2] : 3rd. Drive data set (DDS)
Dependency:
Affects P0320 (motor magnetizing current).
Details:
See P0362 (magnetizing curve flux 1).
MICROMASTER 440 | Parameter List |
63 |