Issue 01/06 | Parameter Description |
P0724 | Debounce time for digital inputs |
| Min: | 0 | ||
| CStat: | CT | Datatype: U16 | Unit: - | Def: | 3 |
| COMMANDS | Active: Immediately | QuickComm.: No | Max: | 3 |
Defines debounce time (filtering time) used for digital inputs.
Possible Settings:
0No debounce time
12.5 ms debounce time
28.2 ms debounce time
312.3 ms debounce time
Level
3
P0725 | PNP / NPN digital inputs |
| Min: | 0 | ||
| CStat: | CT | Datatype: U16 | Unit: - | Def: | 1 |
| COMMANDS | Active: Immediately | QuickComm.: No | Max: | 1 |
Level
3
Switches between active high (PNP) and active low (NPN). This is valid for all digital inputs simultaneously.
The following is valid by using the internal supply:
Possible Settings:
0NPN mode ==> low active
1PNP mode ==> high active
Value:
NPN: Terminals 5/6/7/8/16/17 must be connected via terminal 28 ( O V).
PNP: Terminals 5/6/7/8/16/17 must be connected via terminal 9 (24 V).