Issue 01/06 | Parameter Description |
P2174[3] Torque threshold M_thresh |
| Min: | 0.00 | ||
CStat: | CUT | Datatype: Float | Unit: Nm | Def: | 5.13 |
ALARMS | Active: Immediately | QuickComm.: No | Max: | 99999.00 |
Defines torque threshold for comparing actual torque.
Level
2
M_act > M_thresh
M_actNoAcc > M_thresh
M_act | 1 |
| |
| 0 |
| Delay time torque |
|
| M_act > M_thresh | |||||||
| 0 ... 10000 [ms] |
|
|
| |||||||
| P2176.D (10) |
|
| r2198 Bit10 | |||||||
|
|
|
|
|
|
|
|
|
| M_actNoAcc | |
|
|
|
| T 0 |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| & | > M_thresh | |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| r2198 Bit09 | ||
|
|
|
|
|
|
|
|
|
|
| |
| Delay_T rampUpCmpl |
|
| ||||||||
|
|
|
|
f_act –
+
f_set
Torque threshold
0.00... 99999.00 [Nm] P2174.D (5.13)
Entry freq . deviat
0.00... 20.00 [Hz] P2163.D (3.00)
1 |
0 |
{ |
0 ... 10000 [ms] P2166.D (10)
| T 0 |
|
| (active | SET |
| ||
|
|
| ||||||
|
|
|
|
|
|
| (Q=1) | Q |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| RFG active |
| RESET |
| |||
|
|
|
|
| ||||
|
|
|
|
|
|
| (Q=0) | Q |
Priority
1 RESET
2 SET
|
|
| Hyster freq deviat |
|
|
|
|
|
|
| 0.00 ... 10.00 [Hz] |
|
|
|
|
|
|
| P2164.D (3.00) |
|
|
|
|
Index: | P2174[0] | : 1st. Drive data set (DDS) |
|
|
|
| |
|
|
|
|
| |||
| P2174[1] | : 2nd. Drive data set (DDS) |
|
|
|
| |
| P2174[2] | : 3rd. Drive data set (DDS) |
|
|
|
| |
P2176[3] | Delay time for torque threshold |
| Min: | 0 | Level | ||
| CStat: | CUT | Datatype: U16 | Unit: ms | Def: | 10 | 2 |
| ALARMS | Active: Immediately | QuickComm.: No | Max: | 10000 | ||
|
| ||||||
Index: | Delay time for comparing actual torque to threshold. |
|
|
|
| ||
P2176[0] | : 1st. Drive data set (DDS) |
|
|
|
| ||
|
|
|
|
| |||
| P2176[1] | : 2nd. Drive data set (DDS) |
|
|
|
| |
| P2176[2] | : 3rd. Drive data set (DDS) |
|
|
|
| |
P2177[3] | Delay time for motor is blocked |
| Min: | 0 | Level | ||
| CStat: | CUT | Datatype: U16 | Unit: ms | Def: | 10 | 2 |
| ALARMS | Active: Immediately | QuickComm.: No | Max: | 10000 | ||
|
| ||||||
Index: | Delay time for identification that motor is blocked. |
|
|
|
| ||
P2177[0] | : 1st. Drive data set (DDS) |
|
|
|
| ||
|
|
|
|
| |||
| P2177[1] | : 2nd. Drive data set (DDS) |
|
|
|
| |
| P2177[2] | : 3rd. Drive data set (DDS) |
|
|
|
| |
P2178[3] | Delay time for motor pulled out |
| Min: | 0 | Level | ||
| CStat: | CUT | Datatype: U16 | Unit: ms | Def: | 10 | 2 |
|
| ||||||
| ALARMS | Active: Immediately | QuickComm.: No | Max: | 10000 |
|
Delay time for identification that motor is pulled out.
Index:
P2178[0] : 1st. Drive data set (DDS)
P2178[1] : 2nd. Drive data set (DDS)
P2178[2] : 3rd. Drive data set (DDS)
MICROMASTER 440 | Parameter List |
217 |