Parameter Description | Issue 01/06 |
P0821 | BI: DDS bit 1 |
|
| Min: | 0:0 | |
| CStat: | CT | Datatype: U32 | Unit: - | Def: | 0:0 |
| COMMANDS | Active: first confirm | QuickComm.: No | Max: | 4095:0 |
Level
3
Selects command source from which Bit 1 for selecting a drive data set is to be read in (see parameter P0820).
Common Settings:
722.0= Digital input 1 (requires P0701 to be set to 99, BICO)
722.1= Digital input 2 (requires P0702 to be set to 99, BICO)
722.2= Digital input 3 (requires P0703 to be set to 99, BICO)
722.3= Digital input 4 (requires P0704 to be set to 99, BICO)
722.4= Digital input 5 (requires P0705 to be set to 99, BICO)
722.5= Digital input 6 (requires P0706 to be set to 99, BICO)
722.6= Digital input 7 (via analog input 1, requires P0707 to be set to 99)
722.7= Digital input 8 (via analog input 2, requires P0708 to be set to 99)
Note:
P0820 is also relevant for drive data set (DDS) selection.
3.14BICO command parameters
P0840[3] BI: ON/OFF1 |
|
| Min: | 0:0 | |
CStat: | CT | Datatype: U32 | Unit: - | Def: | 722:0 |
| COMMANDS | Active: first confirm | QuickComm.: No | Max: | 4000:0 |
Allows ON/OFF1 command source to be selected using BICO.
Level
3
The first three digits describe the parameter number of the command source; the last digit denotes the bit setting for that parameter. The default setting (ON right) is digital input 1 (722.0). Alternative source possible only when function of digital input 1 is changed (via P0701) before changing value of P0840.
ON | OFF1 | t |
|
|
f |
|
|
| |
|
|
|
| |
f max |
|
| f act,motor | |
|
|
|
| |
(P1082) |
|
|
|
|
f 2 |
| P2168 | f act,inverter | |
|
| |||
|
|
| ||
P2167 |
|
|
|
|
0 | P2168 | t |
|
|
| tdown,OFF1 = | P1121⋅ | f 2 | |
| tdown,OFF1 | |||
| P1082 | |||
P1120 | P1121 |
|
| |
|
|
| ||
r0052 Bit02 |
|
|
|
|
Operation
Pulse cancellation
Index:
t
P0840[0] : 1st. Command data set (CDS)
P0840[1] : 2nd. Command data set (CDS)
P0840[2] : 3rd. Command data set (CDS)
Common Settings:
722.0= Digital input 1 (requires P0701 to be set to 99, BICO)
722.1= Digital input 2 (requires P0702 to be set to 99, BICO)
722.2= Digital input 3 (requires P0703 to be set to 99, BICO)
722.3= Digital input 4 (requires P0704 to be set to 99, BICO)
722.4= Digital input 5 (requires P0705 to be set to 99, BICO)
722.5= Digital input 6 (requires P0706 to be set to 99, BICO)
722.6= Digital input 7 (via analog input 1, requires P0707 to be set to 99)
722.7= Digital input 8 (via analog input 2, requires P0708 to be set to 99)
19.0= ON/OFF1 via BOP
Dependency:
Active only when P0719 < 10. See parameter P0719 (Selection of command/setpoint source).
Note:
- OFF1 means a ramp stop down to 0 using P1121. - OFF1 is low active.
- For the priority of all soft commands, the following applies: OFF2, OFF3, OFF1
102 | MICROMASTER 440 Parameter List |