Issue 01/06 | Parameter Description |
P2016[8] CI: PZD to BOP link (USS) |
| Min: | 0:0 | ||
CStat: | CT | Datatype: U32 | Unit: - | Def: | 52:0 |
COMM | Active: Immediately | QuickComm.: No | Max: | 4000:0 |
Selects signals (process data PZD) to be transmitted to serial interface via USS on BOP link
Level
3
r0052 | P2016 |
|
|
|
|
r0052 | [0] |
|
|
|
|
r0021 | [1] |
|
|
|
|
| [2] |
|
|
|
|
r0053 | [3] |
|
|
|
|
r0053 | . |
|
|
|
|
| . | PZD4 | PZD3 | PZD2 | PZD1 |
| . | ||||
| [7] | ZSW2 |
| HIW | ZSW1 |
STX | Start of text |
LGE | Length |
ADR | Address |
PKW | Parameter ID value |
PZD | Process data |
BCC | Block check character |
ZSW | Status word |
HIW | Main actual value |
BCC
P2012
PZD |
| PKW |
Process data |
| Parameter |
|
|
|
|
|
|
| USS telegram | |
|
|
|
ADR LGE STX
PZD mapping from parameter P2016 USS on BOP link
Index:
P2016[0] : Transmitted word 0
P2016[1] : Transmitted word 1
P2016[2] : Transmitted word 2
P2016[3] : Transmitted word 3
P2016[4] : Transmitted word 4
P2016[5] : Transmitted word 5
P2016[6] : Transmitted word 6
P2016[7] : Transmitted word 7
Example:
P2016[0] = 52.0 (default). In this case, the value of r0052[0] (CO/BO: Status word) is transmitted as 1st PZD to the BOP link.
Note:
If r0052 not indexed, display does not show an index (".0" ).
MICROMASTER 440 | Parameter List |
199 |