Issue 01/06 | Parameter Description |
P1489[3] Droop scaling |
|
| Min: | 0.00 | |
CStat: | CUT | Datatype: Float | Unit: - | Def: | 0.05 |
CONTROL | Active: Immediately | QuickComm.: No | Max: | 0.50 |
Level
3
Defines amount of droop in per unit at full load in [%].
Index:
P1489[0] : 1st. Drive data set (DDS)
P1489[1] : 2nd. Drive data set (DDS)
P1489[2] : 3rd. Drive data set (DDS)
Note:
If 0 is entered as value, no droop is applied.
r1490 | CO: Droop frequency |
| Min: | - |
| Datatype: Float | Unit: Hz | Def: | - |
|
| Max: | - |
Displays output signal of droop function.
Level
3
This result of droop calculation is subtracted from the speed controller setpoint.
P1492[3] Enable droop |
|
| Min: | 0 | |
CStat: | CUT | Datatype: U16 | Unit: - | Def: | 0 |
CONTROL | Active: first confirm | QuickComm.: No | Max: | 1 |
Enables droop.
Possible Settings:
0Disabled
1Enabled
Index:
P1492[0] : 1st. Drive data set (DDS)
P1492[1] : 2nd. Drive data set (DDS)
P1492[2] : 3rd. Drive data set (DDS)
Dependency:
Effective only if droop scaling P1489 > 0.
Level
3
MICROMASTER 440 | Parameter List |
171 |