Parameter Description | Issue 01/06 |
P1503[3] CI: Torque setpoint |
|
| Min: | 0:0 | |
CStat: | T | Datatype: U32 | Unit: - | Def: | 0:0 |
CONTROL | Active: first confirm | QuickComm.: No | Max: | 4000:0 |
Selects source of torque setpoint for torque control.
Index:
P1503[0] : 1st. Command data set (CDS)
P1503[1] : 2nd. Command data set (CDS)
P1503[2] : 3rd. Command data set (CDS)
Details:
See parameter P1501.
Level
3
r1508 | CO: Torque setpoint |
| Min: | - |
| Datatype: Float | Unit: Nm | Def: | - |
|
| Max: | - |
Displays torque setpoint before limitation.
Details:
See parameter P1501.
Level
2
3.29.2.5Supplementary torque setpoint
P1511[3] CI: Additional torque setpoint |
| Min: | 0:0 | ||
CStat: | T | Datatype: U32 | Unit: - | Def: | 0:0 |
CONTROL | Active: first confirm | QuickComm.: No | Max: | 4000:0 |
Level
3
Selects source of additional torque setpoint for torque and speed control.
Index:
P1511[0] : 1st. Command data set (CDS)
P1511[1] : 2nd. Command data set (CDS)
P1511[2] : 3rd. Command data set (CDS)
Details:
See parameter P1501.
r1515 | CO: Additional torque setpoint |
| Min: | - | Level |
| Datatype: Float | Unit: Nm | Def: | - | 2 |
|
| ||||
|
| Max: | - |
|
Displays additional torque setpoint.
Details:
See parameter P1501.
r1518 | CO: Acceleration torque |
| Min: | - |
| Datatype: Float | Unit: Nm | Def: | - |
|
| Max: | - |
Displays acceleration torque.
Details:
See parameter P1501.
Level
3
P1520[3] CO: Upper torque limit |
|
| Min: | ||
CStat: | CUT | Datatype: Float | Unit: Nm | Def: | 5.13 |
CONTROL | Active: Immediately | QuickComm.: No | Max: | 99999.00 |
Specifies fixed value for upper torque limitation.
P1520def = | 1.5⋅ r0333 |
P1520max = | ± 4 ⋅ r0333 |
Index:
P1520[0] : 1st. Drive data set (DDS)
P1520[1] : 2nd. Drive data set (DDS)
P1520[2] : 3rd. Drive data set (DDS)
Level
2
176 | MICROMASTER 440 Parameter List |