Issue 01/06 | Parameter Description |
r1917[3] | Identified stator inductance 2 |
| Min: | - |
| Datatype: Float | Unit: - | Def: | - |
|
| Max: | - |
Displays identified stator inductance.
Index:
r1917[0] : U_phase
r1917[1] : V_phase
r1917[2] : W_phase
Details:
See P1915 (identified nominal stator inductance)
Level
2
r1918[3] | Identified stator inductance 3 |
| Min: | - |
| Datatype: Float | Unit: - | Def: | - |
|
| Max: | - |
Displays identified stator inductance.
Index:
r1918[0] : U_phase
r1918[1] : V_phase
r1918[2] : W_phase
Details:
See P1915 (identified nominal stator reactance)
Level
2
r1919[3] | Identified stator inductance 4 |
| Min: | - |
| Datatype: Float | Unit: - | Def: | - |
|
| Max: | - |
Displays identified stator inductance.
Index:
r1919[0] : U_phase
r1919[1] : V_phase
r1919[2] : W_phase
Details:
See P1915 (identified nominal stator inductance)
Level
2
r1920[3] | Identified dyn. leak. inductance |
| Min: | - | Level |
| Datatype: Float | Unit: - | Def: | - | 2 |
|
| Max: | - |
| |
Index: | Displays identified total dynamic leakage inductance. |
|
|
|
|
r1920[0] : U_phase |
|
|
|
| |
|
|
|
|
| |
| r1920[1] : V_phase |
|
|
|
|
| r1920[2] : W_phase |
|
|
|
|
r1925 | Identified |
| Min: | - | Level |
| Datatype: Float | Unit: V | Def: | - | 2 |
|
| ||||
|
| Max: | - |
|
Displays identified
r1926 | Ident. gating unit dead time |
| Min: | - |
| Datatype: Float | Unit: us | Def: | - |
|
| Max: | - |
Displays identified dead time of gating unit interlock.
Level
2
P1930 | Voltage setpoint for calibration |
| Min: | 0 | ||
| CStat: | CUT | Datatype: Float | Unit: V | Def: | 0 |
| INVERTER | Active: Immediately | QuickComm.: No | Max: | 1000 |
Specifies reference voltage for generation of a test voltage vector (e.g. used for shunt calibration).
Level
4
P1931 | Phase |
|
|
| Min: | 1 |
| CStat: | CUT | Datatype: U16 | Unit: - | Def: | 1 |
| INVERTER | Active: Immediately | QuickComm.: No | Max: | 6 |
Defines phase of voltage vector
Level
4
MICROMASTER 440 | Parameter List |
191 |