Issue 01/06 | Parameters |
2.2Quick commissioning (P0010 = 1)
The following parameters are necessary for quick commissioning (P0010 = 1).
Quick commissioning (P0010 = 1)
| Name | Access level | Cstat |
P0100 | Europe / North America | 1 | C |
P0205 | Inverter application | 3 | C |
P0300 | Select motor type | 2 | C |
P0304 | Motor voltage rating | 1 | C |
P0305 | Motor current rating | 1 | C |
P0307 | Motor power rating | 1 | C |
P0308 | Motor cosPhi rating | 1 | C |
P0309 | Motor efficiency rating | 1 | C |
P0310 | Motor frequency rating | 1 | C |
P0311 | Motor speed rating | 1 | C |
P0320 | Motor magnetizing current | 3 | CT |
P0335 | Motor cooling | 2 | CT |
P0640 | Motor overload factor [%] | 2 | CUT |
P0700 | Selection of command source | 1 | CT |
P1000 | Selection of frequency setpoint | 1 | CT |
P1080 | Min. speed | 1 | CUT |
P1082 | Max. speed | 1 | CT |
P1120 | 1 | CUT | |
P1121 | 1 | CUT | |
P1135 | OFF3 | 2 | CUT |
P1300 | Control mode | 2 | CT |
P1500 | Selection of torque setpoint | 2 | CT |
P1910 | Select motor data identification | 2 | CT |
P1960 | Speed control optimisation | 3 | CT |
P3900 | End of quick commissioning | 1 | C |
When P0010 = 1 is chosen, P0003 (user access level) can be used to select the parameters to be accessed. This parameter also allows selection of a
At the end of the quick commissioning sequence, set P3900 = 1 to carry out the necessary motor calculations and clear all other parameters (not included in P0010 = 1) to their default settings.
Note
This applies only in Quick Commissioning mode.
Reset to Factory default
To reset all parameters to the factory default settings; the following parameters should be set as follows:
Set P0010 = 30
Set P0970 = 1
Note
The reset process takes approximately 10 seconds to complete. Reset to Factory default
MICROMASTER 440 | Parameter List |
15 |