Parameter Description | Issue 01/06 |
r0313[3] | Motor pole pairs |
| Min: | - |
| Datatype: U16 | Unit: - | Def: | - |
|
|
| Max: | - |
Displays number of motor pole pairs that the inverter is currently using for internal calculations.
Index:
r0313[0] : 1st. Drive data set (DDS)
r0313[1] : 2nd. Drive data set (DDS)
r0313[2] : 3rd. Drive data set (DDS)
Value:
Level
3
r0313 = 1 :
r0313 = 2 :
Dependency:
Recalculated automatically when P0310 (rated motor frequency) or P0311 (rated motor speed) is changed.
r0313 = 60 ⋅ P0310P0311
P0314[3] Motor pole pair number |
|
| Min: | 0 | Level | ||
| CStat: | C | Datatype: U16 | Unit: - | Def: | 0 | 3 |
|
| ||||||
| MOTOR | Active: first confirm | QuickComm.: Yes | Max: | 99 |
|
Specifies number of pole pairs of motor.
Index:
P0314[0] : 1st. Drive data set (DDS)
P0314[1] : 2nd. Drive data set (DDS)
P0314[2] : 3rd. Drive data set (DDS)
Value:
P0314 = 1 :
P0314 = 2 :
Dependency:
Recalculated automatically when P0310 (rated motor frequency) or P0311 (rated motor speed) is changed.
P0320[3] Motor magnetizing current |
| Min: | 0.0 | ||
CStat: | CT | Datatype: Float | Unit: % | Def: | 0.0 |
MOTOR | Active: Immediately | QuickComm.: Yes | Max: | 99.0 |
Level
3
Defines motor magnetization current in [%] relative to P0305 (rated motor current).
Index:
P0320[0] : 1st. Drive data set (DDS)
P0320[1] : 2nd. Drive data set (DDS)
P0320[2] : 3rd. Drive data set (DDS)
Dependency:
Setting P0320 = 0: causes calculation by
-P0340 = 1 (data entered from rating plate) or by
-P3900 = 1 - 3 (end of quick commissioning). The calculated value is displayed in parameter r0331.
r0330[3] | Rated motor slip |
| Min: | - |
| Datatype: Float | Unit: % | Def: | - |
|
|
| Max: | - |
Level
3
Displays nominal motor slip in [%] relative to P0310 (rated motor frequency) and P0311 (rated motor speed).
|
|
| P0310− | P0311⋅ r0313 |
|
|
|
| ||
| r0330[%] = |
| 60 |
| ⋅ 100% |
|
|
|
| |
|
| P0310 |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |
Index: | r0330[0] | : 1st. Drive data set (DDS) |
|
|
|
| ||||
|
|
|
|
| ||||||
| r0330[1] | : 2nd. Drive data set (DDS) |
|
|
|
| ||||
| r0330[2] | : 3rd. Drive data set (DDS) |
|
|
|
| ||||
r0331[3] | Rated magnetization current |
| Min: | - | Level | |||||
|
|
|
|
| Datatype: Float | Unit: A | Def: | - | 3 | |
|
|
|
|
| Max: | - |
|
Displays calculated magnetizing current of motor in [A].
Index:
r0331[0] : 1st. Drive data set (DDS)
r0331[1] : 2nd. Drive data set (DDS)
r0331[2] : 3rd. Drive data set (DDS)
54 | MICROMASTER 440 Parameter List |