Prerequisites

for

ATM

Troubleshooting

 

 

In order

to

determine

the cause

of

a problem during installation of 6416SW and ATM

media modules

or

after

turning ON

the

hub:

The correct microcode must be installed. 6416SW LEDs must function properly.

6416SW and ATM media modules must be plugged into the hub.

To ensure that these conditions are satisfied, follow these steps:

1. From

the

Distributed

Management

Module

(DMM),showentermodule 18.1 verbose

 

 

 

 

and verify that the level

of

the Fault-Tolerant Controller (RCTL) code

is

at

least

v1.01. If it is not, the

hub

slots

in

which

ATM

media

modules are

installed

may not

receive

power.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Make

sure that

the

6416SW

and

ATM media modules are properly inserted in their

slots

and

are

plugged

 

into

the

connectors in the ATM backplane of

the

hub.

 

3. Verify

that

all

6416SW

and

ATM

media LEDs are functioning properly

by

pressing

the

LED Test

button on

the

Fault-Tolerant Controller (RCTL) module. If one or

 

more LEDs on a 6416SW or ATM

media module

do

not

light

ON, replace

the

 

 

module(s).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-3

Page 133
Image 133
3Com 6416SW manual Troubleshooting, Prerequisites