Setting

Up

a Configuration

Console

in

Normal

 

 

(ASCII)

Mode

 

 

 

 

 

 

The

following

procedure sets

up

the

configuration

console

in Normal mode and logs you

on

as the

system administrator

with

full

access

to all

6416SW commands:

1.Connect an ASCII-type terminal to the RS-232 console port on the front panel of the 6416SW.

2.In the terminal’s user guide, locate the procedure for setting parameters for bau

rate, data bits, parity, and stop bits.

3. Configure

these configuration

console

settings

to

the

values used by the 6416SW

so that

the

configuration console and the 6416SW can communicate. The

factory-set

default settings

for the

6416SW

are

as

follows:

Baud

rate

9600

 

 

 

 

 

Data

bits

8

 

 

 

 

 

Parity

 

None

 

 

 

 

 

Stop

bits

 

1

 

 

 

 

 

4. Press Enter. The following message is displayed:

￿ATM Switch/Control Module

(c)Copyright IBM Corp. 1994, 1996. All rights reserved. Password:

5.As no factory password is provided for administration first Logon, press Enter.

￿Welcome to system administrator service on ONcore. ONcoreATM>

You can now proceed to configure the 6416SW, as described in Chapter 5, “Configuring the ATM Switch/Control Module” on page 5-1.