5. Press the ATM Reset button on the 6416SW module.

6.If the ACTIVE LED still does not light, call your 3Com dealer or your 3Com representative.

MAINT

LED is lit

and you

have

not entered

the MAINTAIN

command.

Steps

to

Take:

 

 

 

 

 

1. Make

sure

that

the

console

cable is

plugged into the topmost RS-232 port on the

front

panel

of

the

6416SW module.

 

2.

Enter

the

BOOT

command.

 

 

MAINT

LED

is lit,

ONcore

stays

in Maintenance

Mode.

 

 

 

Steps

 

to

Take:

 

 

 

 

 

 

 

 

 

1. The

 

6416SW

is

badly plugged. Replug the 6416SW. When you feel that the

 

module

is

almost

inserted,

use

the levers to push it

in completely. (see

Figure 2-2

on

page 2-4.)

 

 

 

 

 

 

 

 

2.

A

pin

is

bent

on

one

of

the

6416SW

connectors. Check

the rear of the

6416SW.

3.

A

backplane pin

is

bent.

Check

the

backplane.

 

 

4. Hardware failure on the board. Record the error code of the prompt in the Maintenance Mode (for example,>>0020 >, then refer to “Maintenance Codes” on

page C-5.