Setup Pages
88 MVP-7500/8400 Modero Viewpoint Wireless Touch Panels
Features on this page include:
FIG. 79 Panel Information Page (MVP-8400)
Panel Information Page
Back: Saves all changes and returns to the previous page.
WiFi/Wired icon: The icon to the left of the Connection Status Icon displays whether the current
connection to the Master is Wireless (image of a radio antenna) or Wired
(image of three networked computers).
Connection Status icon: The icon in the upper-right corner of each Setup page shows online/offline state
of the panel to the master.
Bright red - disconnected
Bright green - connected. Blinks when a blink message is received to dark
green every 5 seconds for half a second then go back to bright green.
Bright yellow - panel missed a blink message from the master. It will remain
yellow for 3 missed blink messages and then turn red. It will return to green
when a blink message is received.
Note: a Lock appears on the icon if the panel is connected to a secured NetLinx
Master.
Panel Type: Displays the model of the panel being used.
Firmware Version: Displays the version number of the G4 firmware loaded on the panel.
Setup Port: Displays the setup port information (value) being used by the panel.
High Port: Displays the high port (port count) value for the panel.
High Address: Displays the high address (address count) value for the panel.
High Channel: Displays the high channel (channel count) value for the panel.
High Level: Displays the high level (level count) value being used by the panel.
Serial Number: Displays the specific serial number value assigned to the panel.
Setup Pages Version: Displays the type and version of the Setup pages being used by the panel.
Screen Width: Displays the screen width (in pixels).
MVP-8400 = 800
Screen Height: D isplays the screen height (in pixels).
MVP-8400 = 600 pixels.
Screen Refresh Rate: Displays the video refresh rate applied to the incoming video signal from the
panel.
Screen Rotation: Displays the degree of rotation applied to the on-screen image.
Power Up Pages: Displays the page assigned to display after the panel is powered-up.
Start Up String: Displays the start-up string.
Wake Up String: Displays the wake up string used after an activation from a timeout.