Configuring Communications
3.Click the Communications Settings button to open the Communications Settings dialog.
4.Click the NetLinx Master radio button (from the Platform Selection section).
5.Click the Virtual Master radio button (from the Transport Connection Option section).
6.Click the Edit Settings button to open the Virtual NetLinx Master Settings dialog (FIG. 28).
7.Enter the System number (default is 1).
8.Click OK to close all open dialogs and save your settings.
9.Click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System.
10.
The panel will not appear as a device below the virtual system number (in the Online Tree tab) until both the system number (default = 1) is entered into the Master Connection section of the System Settings page and the panel is restarted.
The Connection status turns green after a few seconds to indicate an active USB connection to the PC (Virtual Master).
If the System Connection icon does not turn green, check the USP connection and communication settings and refresh the system.
Ethernet
1.When using Ethernet, press the listed Mode to toggle through the available connection modes:
Connection Modes
Mode | Description | Procedures | |
|
|
| |
Auto | The device connects to the first master that | Setting the System Number: | |
| responds. This setting requires you set the | 1. | Select the System Number to open the keypad. |
| System Number. | 2. | Set your System Number select Done. |
|
| ||
|
|
| |
URL | The device connects to the specific IP of a | Setting the Master IP: | |
| master via a TCP connection. This setting | 1. | Select the Master IP number to the keyboard. |
| requires you set the Master’s IP. | 2. | Set your Master IP and select Done. |
|
| ||
|
|
| |
Listen | The device "listens" for the master to initiate | Confirm device IP is on the Master URL list. You | |
| contact. This setting requires you provide the | can set the Host Name on the device and use it to | |
| master with the device’s IP. | locate the device on the master. Host Name is | |
|
| particularly useful in the DHCP scenario where the | |
|
| IP address can change. | |
|
|
|
|
2.Select the Master Port Number to open the keypad and change this value. The default setting for the port is 1319.
3.Set your Master Port and select Done.
If you have enabled password security on your master you need to set the username and password within the device.
4.Select the blank field Username to open the keyboard.
5.Set your Username and select Done.
6.Select the blank field Password to open the keyboard.
7.Set your Password and select Done.
8.Press the Back button to return to the Protected Setup page.
9.Press the Reboot button to reboot device and confirm changes.
Master Connection to a Virtual Master via Ethernet
When configuring your panel to communicate with a Virtual Master (on your PC) via wireless Ethernet, the Master IP/URL field must be configured to match the IP Address of the PC and make sure to use the Virtual System value assigned to the Virtual Master within NetLinx Studio.
Before beginning:
1.Verify the panel has been configured to communicate with the Wireless Access Point and verify the signal strength quality bargraph is On.
32 |