Configuring Communications

Setting the Panel’s Device Number

In the Protected Setup page:

1.Press the Device Number field to open the Device Number keypad (FIG. 14).

FIG. 14 Protected Setup page

Enter a unique Device Number assignment for the panel, and press Done to return to the Protected Setup page. The Device Number range is 1 - 32000, the default is 10001.

2.Press Reboot to reboot the panel, and apply the new Device Number.

Wireless Settings Page - Wireless Access Overview

Hot Swapping

Hot swapping is not an issue on these panels as the card is installed within the unit and cannot be removed without first removing the housing.

In the case of DHCP, there must be a DHCP server accessible before the fields are populated.

If the SSID (Network Name) and WEP fields have not previously been configured, the

Wireless Settings page will not work until the panel is rebooted.

Before selecting Ethernet as the Master Connection Type you must setup the parameters of the wireless card. The

Wireless Access Point communication parameters must match those of the pre-installed wireless CF card inside the MVP.

The MVP touch panels allow users to connect to a wireless network through their use of the

pre-installed AMX 802.11g wireless interface card to communicate with a Wireless Access Point (WAP) such as the NXA-WAP200G). The WAP communication parameters must match those of the

pre-installed wireless interface card installed within the panel. This internal card transmits data wirelessly using the 802.11x signals at 2.4 GHz. For a more detailed explanation of the new security and encryption technology, refer to the section of the document entitled: Appendix B - Wireless Technology section on page 163.

For more information on utilizing the AMX Certificate Upload Utility in conjunction with the EAP security, refer to the section of the document entitled: Appendix B - Wireless Technology section on page 163.

Configuring a Wireless Network Access

When working with a wireless card, the first step is to configure wireless communication parameters within the Wireless Settings page. This page only configures the card to communicate to a target WAP (such as the NXA-WAP200G), it is still necessary to tell the panel which Master it should be communicating with. This "pointing to a Master" is done via the System Settings page where you configure the IP Address, System Number and Username/Password information assigned to the target Master.

20

MVP-7500/8400 Modero Viewpoint Wireless Touch Panels

Page 34
Image 34
AMX MVP-7500/8400 Wireless Settings Page Wireless Access Overview, Configuring a Wireless Network Access, Hot Swapping