Upgrading MVP Firmware

10.Click the Reboot Device checkbox. This causes the touch panel to reboot after the firmware update process is complete. The reboot of the panel can take up 30 seconds after the firmware process has finished.

11.Click Send to begin the transfer. The file transfer progress is indicated on the bottom-right of the dialog.

12.As the panel is rebooting, temporarily unplug the USB connector on the panel until the panel has completely restarted.

13.Once the first panel page has been displayed, reconnect the USB connector to the panel.

14.Right-click the associated System number and select Refresh System. This causes a refresh of all project systems, establishes a new connection to the Master, and populates the System list with devices on your particular system.

15.After the panel powers-up, press and hold the two lower buttons on both sides of the display for 3 seconds to continue with the setup process and proceed to the Setup page.

16.Press the Batteries button (located on the lower-left) to open the Batteries page and confirm the new firmware does not read 0.00.

If the Base Version field displays 0.00, this means there was an error in the firmware upload process. Re-install the base firmware and re-confirm that the new base version no longer reads 0.00.

Although firmware upgrades can be done over wireless Ethernet; it is recommended that firmware KIT files be transferred over a direct USB connection and only when the panel is connected to a power supply. If battery power or wireless connection fails during a firmware upgrade, the panel flash file system may become corrupted.

MVP-7500/8400 Modero Viewpoint Wireless Touch Panels

45

 

 

Page 59
Image 59
AMX MVP-7500/8400 manual Upgrading MVP Firmware